WRIGHTS LANE SYNTHES USA PRODUCTS LLC RADIOLUCENT INSERTION HANDLE FOR EXPERT ALFN/100MM; ROD,FIXATION,INTRAMEDULLARY
|
Back to Search Results |
|
| Model Number |
03.010.488 |
| Medical Device Problem Code |
Failure to Align (2522)
|
| Health Effect - Clinical Code |
No Code Available (3191)
|
| Date of Event |
03/07/2018
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Device was used for treatment, not diagnosis device is an instrument and is not implanted / explanted.(b)(6).The device was received and the product evaluation is in progress.No conclusion can be drawn.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Event or Problem Description
|
|
It was reported that the screws would not go in the aiming arm when the surgeon was attempting to insert the proximal locking screws in an adolescent femoral nail during an intramedullary nail of a femur on (b)(6) 2018.The sales consultant further explained that the aiming arm would accept the drill bit, but not the screws.The insertion handle and/or the aiming arm kept the protection sleeve from lining up properly, which eventually led to the transverse interlock not working properly and they had to switch the hole and use the antegrade interlock to lock the screw and complete the procedure.The procedure was successfully completed with no surgical delay.The patient was fine at the end of the procedure.Concomitant device (s) reported: 12.0mm/8.0mm protection sleeve (part # 03.010.063, unknown lot #, qty # 1).This report is for one (1) radiolucent insertion handle.This is report 3 of 3 for (b)(4).
|
| |
|
Additional Manufacturer Narrative
|
|
A device history record review was performed for the subject device: part no.: 03.010.488.Lot no.: 8402439.Manufacturing location: (b)(4).Release to warehouse date: 31.May.2013.No non conformances (ncrs) were generated during production.Review of the device history record(s) showed that there were no issues during the manufacture of the product that would contribute to this complaint condition.A product investigation was performed for the subject device: it was reported that the screws would not go in the aiming arm when the surgeon was attempting to insert the proximal locking screws in an adolescent femoral nail during an intramedullary nail of a femur on march 7, 2018.The sales consultant further explained that the aiming arm would accept the drill bit, but not the screws.The insertion handle and/or the aiming arm kept the protection sleeve from lining up properly, which eventually led to the transverse interlock not working properly and they had to switch the hole and use the antegrade interlock to lock the screw and complete the procedure.The procedure was successfully completed with no surgical delay.The patient was fine at the end of the procedure.The reported complaint condition of device interaction could not be confirmed or replicated at customer quality (cq) because only the aiming arm and insertion handle were returned.Post manufacturing damage in the form of a burr was observed on the inferior side of the insertion handle hole.Therefore, this complaint is confirmed for post manufacturing damage.The returned insertion handle was manufactured in may 2013 and is over 4 years old.No ncrs were generated during production.Review of the device history record(s) showed that there were no issues during the manufacture of the product that would contribute to this complaint condition.The material and relevant material properties were determined to be conforming at the time of manufacture based on review of the dhr.The following drawing was reviewed during investigation.Insertion handle.The design history was not found to impact the complaint condition.During the investigation no product design issues or discrepancies were observed that may have contributed to the complaint condition.The returned parts were determined to be suitable for the intended use when employed.The radiolucent insertion handle is part of the titanium cannulated adolescent lateral femoral nail ¿ ex insertion instrument set (01.116.044).When fully assembled as an aiming arm construct, the radiolucent insertion handle is a multi-use device that is used to guide recon and standard screws into the adolescent lateral entry femoral nail.A dimensional inspection of features relevant to this complaint could not be obtained at cq due to the post manufacturing damage.The recon femoral nailing implants - core dossier design & clinical risk management (dcrm) was reviewed and the dcrm adequately addresses this complaint.No design issues or manufacturing discrepancies were identified during this investigation.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|