• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: PENUMBRA, INC. PENUMBRA COIL 400; HCG, KRD

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

PENUMBRA, INC. PENUMBRA COIL 400; HCG, KRD Back to Search Results
Catalog Number 4002C1660
Medical Device Problem Code Detachment Of Device Component (1104)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 03/06/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
This device is available for return.A follow up mdr will be submitted upon completion of the device investigation.This report is associated with mfr report number: 3005168196-2018-00678.
 
Event or Problem Description
The patient was undergoing a coil embolization procedure in the ophthalmic artery using penumbra coils 400 (pc400¿s) and a px slim delivery microcatheter (px slim).It was noted that the patient's anatomy was tortuous.During the procedure, while attempting to place the first pc400 into the aneurysm, the pc400 migrated down into the parent vessel; therefore, the physician decided to retract the pc400.While attempting to retract the pc400, it unintentionally detached with approximately four centimeters of the coil outside of the px slim.Therefore, the physician attached a syringe to the back of the px slim and applied suction to successfully remove the px slim and detached pc400 together.Upon removal of the px slim, it was noticed that the px slim was broken at the mid-shaft.The procedure was completed using the same sheath, a new px slim and additional pc400¿s.There was no report of an adverse effect to the patient.
 
Additional Manufacturer Narrative
Results: the pc400 pusher assembly was kinked approximately 20.0 and 112.0 cm from its proximal end (figure 4).The distal detachment tip (ddt) was sheared off and the embolization coil was detached.Conclusions: evaluation of the returned px slim revealed a fracture on the catheter¿s mid-shaft.This damage was likely a result of retracting the device against resistance.This is further supported by the material deformation near the fracture location.Further evaluation revealed a kink near the hub of the device.This damage was likely incidental and occurred post-procedure.Evaluation of the returned pc400 revealed the ddt sheared off of the pusher assembly and the embolization coil was detached within the returned px slim.This ddt likely sheared off as a result of being retracted against resistance.If the pc400 is retracted through a temporarily ovalized or necked catheter, ddt shearing may result.The resistance contributing to both the reported failures in this complaint may have been due to interactions between the devices being used and difficulty, tortuous anatomy.Penumbra catheters and coils are visually inspected during in-process inspection and during quality inspection after manufacturing.The manufacturing records for this lot were reviewed and did not reveal any outstanding discrepancies, design, or quality concerns.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PENUMBRA COIL 400
Common Device Name
HCG, KRD
Manufacturer (Section D)
PENUMBRA, INC.
one penumbra place
alameda CA 94502
MDR Report Key7397470
Report Number3005168196-2018-00679
Device Sequence Number16160489
Product Code HCG
UDI-Device Identifier00814548010724
UDI-Public00814548010724
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K120330
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 03/06/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Physician
Device Expiration Date04/08/2025
Device Catalogue Number4002C1660
Device Lot NumberF75542
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/24/2018
Initial Date Received by Manufacturer 03/06/2018
Supplement Date Received by Manufacturer05/07/2018
Initial Report FDA Received Date04/04/2018
Supplement Report FDA Received Date05/22/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-