Patient information is not available for reporting.Unknown when device malfunctioned.Device is an instrument and is not implanted/explanted.The subject device has been received and the product evaluation is in progress.No conclusion can be drawn.A review of the device history records has been requested and is currently pending completion.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Part 312.240, lot 8084034: manufacturing location: bettlach.Release to warehouse date: october 10, 2012.No non-conformance reports (ncrs) were generated during production.Review of the device history record (dhr) showed that there were no issues during the manufacture of the product that would contribute to this complaint condition.A product investigation was completed: per the technique guide, the 312.240 2.7mm/2.0mm double drill sleeve is an instrument routinely used in the 2.4mm/2.7mm variable angle lcp forefoot/midfoot system.The 312.240 lot number 8084034 2.7mm/2.0mm double drill sleeve was returned and reported to have broken during surgery.This condition is confirmed; the barrel of the 2.0mm end has broken off at the base where it meets the handle.This complaint condition was likely caused by over five years of consistent use and possible rough handling during surgery or sterile processing; however, this complaint is not likely a result of any design or manufacturing related deficiency.A visual inspection, dhr review, and drawing review were performed as part of this investigation.No new malfunctions were observed during the course of this investigation.The device was manufactured in october 2012 and is over five years old.The balance of the returned device is in fairly worn condition with markings and signs of wear along its length.The relevant drawing was reviewed during this investigation.The condition of the returned device does agree with the complaint description.Whether the complaint condition for this device can be replicated is not applicable for this condition.Upon review of the device history record, no ncrs, material defects, or hardness issues relevant to the complaint condition were generated during the production of this device.A dimensional inspection was not able to be performed due to the device breakage.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|