| Catalog Number |
GLY120715 |
| Medical Device Problem Codes |
Positioning Failure (1158); Premature Activation (1484)
|
| Health Effect - Clinical Code |
No Consequences Or Impact To Patient (2199)
|
| Date of Event |
03/19/2018
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
(b)(4).The patient identifier is not known.The patient¿s age is not known.The patient's weight is not known.(b)(4).Concomitant med products: spectra coils, enterprise stents, detachment control box, connecting cable, other brands coils.(b)(6); the initial reporter email is not available.(b)(4).The galaxy g3 7 mm x 15 cm product was not returned for investigation.A review of manufacturing documentation associated with this lot (l10379) presented no issues during the manufacturing or inspection processes related to the reported complaint.There were no nonconformances related to device manufacture or inspection.All product rejected during manufacturing was identified as scrap and properly accounted for.The reported issue of failure to detach and premature detachment of the coil in the microcatheter during the coil removal could not be confirmed without the device return for analysis.The root cause of the event could not be determined; however, procedural / handling factors may have contributed to the event.Additional information will be submitted within 30 days of receipt.
|
| |
|
Event or Problem Description
|
|
The healthcare professional reported that during the coil embolization procedure the healthcare professional reported that during the coil embolization procedure of a terminal wide neck (approximately 12 mm wide) aneurysm on the basilar bifurcation that began with y stenting using two enterprise stent followed by the placement of six spectra coils; the sixth coil, the galaxy g3 7 mm x 15 cm (gly120715 / l10379) did not detach after the physician made four attempts to detach it.The coil was removed and during removal, it detached in the microcatheter.The microcatheter was removed with the coil to ensure no major complications to the patient.It was confirmed that the event did not result in any interruption of blood flow.The coil was not stretched when it was removed; the coil was still attached to the delivery system when it was being retracted into the microcatheter but became detached from the delivery system when the coil detached in the microcatheter.The same detachment control box (dcb2000500 / c50934) and connecting cable (ccb00015700) were used to detach the subsequent coils.The procedure was completed without further complications with other brands of coils, a total of 26 coils including the first six spectra coils; there was no report of any patient injury or complication; the reported event did not result in a significant clinical delay in the procedure.
|
| |
|
Search Alerts/Recalls
|