BARD ACCESS SYSTEMS PROV 3F SL IR 70CM NI; CATHETER,INTRAVASCULAR,THERAPEUTIC,LONG-TERM GREATER THAN 30 DAYS Back to Search Results
Catalog Number S3173355
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.The device has not been returned to the manufacturer for evaluation.A lot history review (lhr) review is not possible, as no manufacturing lot number has been provided by the complainant.(b)(4).
 
Event or Problem Description
It was reported that the patient's picc was "complicated by a fracture of an external component, requiring replacement.".No patient injury reported.
 
Additional Manufacturer Narrative
The following were reviewed as part of this investigation: patient severity, frequency analysis, applicable previous investigation(s), sample (if available), applicable fmea documents, labeling, and applicable manufacture records.Based on a review of this information, the following was concluded: the complaint of a leak is confirmed.One 3 fr sl power picc catheter was returned for investigation.The catheter appeared to have been trimmed 1 cm from the distal end of the molded wing.The catheter was flushed with water using a 12 ml syringe and a leak was observed at the hub/extension tubing interface.Microscopic observation revealed a partial split in the extension tubing.The fracture surface of the split was rough and exhibited cracks/fissures and beach marks, which are indicative of material fatigue.
 
Event or Problem Description
It was reported that the patient's picc was "complicated by a fracture of an external component, requiring replacement." no patient injury reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PROV 3F SL IR 70CM NI
Common Device Name
CATHETER,INTRAVASCULAR,THERAPEUTIC,LONG-TERM GREATER THAN 30 DAYS
Manufacturer (Section D)
BARD ACCESS SYSTEMS
605 n. 5600 w.
salt lake city UT 84116
MDR Report Key7403714
Report Number3006260740-2018-00636
Device Sequence Number1456345
Product Code LJS
UDI-Device Identifier00801741129971
UDI-Public(01)00801741129971
Combination Product (Y/N)N
Initial Reporter StateMI
Initial Reporter CountryUS
PMA/510(K) Number
K162443
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type User Facility
Initial Reporter Occupation Other Health Care Professional
Remedial Action Other,Notification
Type of Report Initial,Followup
Report Date (Section B) 02/14/2019
Report Date (Section F) 03/14/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue NumberS3173355
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/18/2019
Event Location Hospital
Date Report to Manufacturer03/14/2018
Initial Date Received by Manufacturer Not provided
Supplement Date Received by Manufacturer02/06/2019
Initial Report FDA Received Date04/06/2018
Supplement Report FDA Received Date02/14/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age21 MO
-
-