| Catalog Number |
FG200000 |
| Medical Device Problem Code |
Image Orientation Incorrect (1305)
|
| Health Effect - Clinical Code |
No Consequences Or Impact To Patient (2199)
|
| Date of Event |
03/20/2018
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
The hardware investigation has begun but it has not been completed at this time.When the investigational analysis has been completed, a supplemental 3500a report will be submitted.(b)(4).
|
| |
|
Event or Problem Description
|
|
It was reported that a female patient underwent a procedure with a carto ent system wherein the carto ent navigation system did not accurately display the anatomy of the left sided sinuses.When dilation of the right-sided sinuses was performed the anatomy was displayed properly.When the left-sided sinuses were being dilated the system still displayed the balloon as if in the right-sided sinuses.The customer re-registered anatomy twice with the registration probe without resolution.No errors were present.The physician abandoned use of the navigation system and proceeded with the case manually with the luma wire.On 04/06/2018, additional information was received confirming the procedure was completed successfully using an ultirra ballon without navigation.It also confirms that no patient consequences were reported during the case.The patient did not require medical or surgical intervention neither extended hospitalization, however, this event has been determined to be a reportable malfunction.
|
| |
|
Additional Manufacturer Narrative
|
|
It was reported that a female patient underwent a procedure with a carto ent system wherein the carto ent navigation system did not accurately display the anatomy of the left sided sinuses.When dilation of the right-sided sinuses was performed the anatomy was displayed properly.When the left-sided sinuses were being dilated the system still displayed the balloon as if in the right-sided sinuses.No errors were present on the equipment and no patient consequences were reported during the case.Device evaluation summary: a biosense webster inc., field service engineer (fse) arrived on site to troubleshoot the reported issue.It was found that the metal on the chair was causing system to fail cube test and inaccurate magnetic location.When padding was added between the chair and cube, system passed and issue resolved.Fse advised the bwi representative and the customer to add a mattress under the patient.System is operational.A device history record (dhr) review was performed by the manufacturer and no anomalies, which are related to the reported issue were noted in manufacturing or servicing of this equipment.Manufacturer's ref.No: (b)(4).
|
| |
|
Search Alerts/Recalls
|