LEMAITRE VASCULAR, INC. SINGLE LUMEN EMBOLECTOMY CATHETER Back to Search Results
Catalog Number 1601-38
Medical Device Problem Code Deflation Problem (1149)
Health Effect - Clinical Code Foreign Body In Patient (2687)
Date of Event 03/07/2018
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
We have not received the device for evaluation.However, we have received the picture of the defective device from our distributor.The catheter shown in the picture was not manufactured by lemaitre.At this time, we are still investigating if a wrong device was sent to the distributor by the hospital or the wrong device was reported by the hospital.The investigation is ongoing.A follow-up report will be provided if we determine it was the lemaitre single lumen catheter that resulted in this incident.Our review of the lot history records for the reported lot number did not find any discrepancies either in the manufacturing or packaging process that could be related to this incident.Further, we have not received any other complaints of similar nature for devices from this lot.The distributor who reported this incident to us had tried several times to reach the contact person in the hospital by phone and also went there twice personally, but was unable to obtain any more information on this incident.At this time, we are unable to confirm that a lemaitre device was involved in this issue.However, should we confirm the device to be manufactured by lemaitre vascular, inc, then we will apply trending and root cause analysis to determine if further corrective action is required.
 
Event or Problem Description
The catheter was stuck upon entering a collateral variant of the superficial femoral artery because the balloon did not deflate.It was initially not possible to remove the balloon, even after puncturing it.It was necessary to dry the collateral variant to remove the catheter.
 
Additional Manufacturer Narrative
This is a follow-up report with reference to manufacturer's report # 1220948-2018-00014 that was previously submitted on 04/12/2018.During our initial report, we could not verify if the device involved in this incident was a lemaitre embolectomy catheter since the picture sent by the hospital contained label with a different lot number and catalog number in which the device was packaged.On 13/04/2018, we were able to confirm that the device was indeed a lemaitre embolectomy catheter but was packaged in a bag with different reference no.And lot no.Label.We have not yet received the device for evaluation.However, we have received additional pictures of the device that displayed the defects in this device.The lumen of the catheter had separated about 6 inches below from the tip of the catheter.The proximal ligature had slipped from its intended position and seems to have covered the inflation hole.As a result, the surgeon could not deflate the balloon.From our investigation for similar complaints, we have found that this type of defect occurs when the balloon is pulled with excessive force during the procedure.It is possible that the tortuous anatomy of the patient, calcified plaque if present in the patient's vessel and excessive tension on the device during the procedure could also lead to this failure.As stated in ifu, to minimize the risk of balloon rupture/separation, maximum recommended inflation volume and pull force for the catheter should not be exceeded.We have conducted a lot history review and did not find any issues noted in the manufacturing or packaging process that could be related to this issue.All qc tests passed their requirements.We perform 100% inspection on each device to ensure that the ligature properly binds to the shaft and an adequate amount of glue is present in the ligature.However, it is also possible that the tension on the ligature or the glue applied underneath the balloon prior to the balloon tying process was inadequate in this device resulting in the slippage of the ligature from its position.We have not received any other complaints of a similar nature for devices from this lot.We have requested for additional information from the hospital related to this incident.However, we have not received any response back from the hospital.We currently have a corrective and preventive action (capa) opened to investigate possible root causes of this issue.The corrective action includes review of our manufacturing processes, materials and handling of the device.
 
Event or Problem Description
The catheter was stuck upon entering a collateral variant of the superficial femoral artery because the balloon did not deflate.It was initially not possible to remove the balloon, even after puncturing it.It was necessary to dry the collateral variant to remove the catheter.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SINGLE LUMEN EMBOLECTOMY CATHETER
Common Device Name
EMBOLECTOMY CATHETER
Manufacturer (Section D)
LEMAITRE VASCULAR, INC.
63 second ave
burlington MA 01803
MDR Report Key7426568
Report Number1220948-2018-00014
Device Sequence Number11191793
Product Code DXE
UDI-Device Identifier00840663100477
UDI-Public00840663100477
Combination Product (Y/N)N
Initial Reporter CountryPO
PMA/510(K) Number
K992368
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,distri
Initial Reporter Occupation Nurse
Type of Report Initial,Followup
Report Date (Section B) 05/09/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Physician
Device Expiration Date07/28/2023
Device Catalogue Number1601-38
Device Lot NumberSLC4316
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Initial Date Received by Manufacturer 03/13/2018
Supplement Date Received by Manufacturer03/14/2018
Initial Report FDA Received Date04/12/2018
Supplement Report FDA Received Date05/09/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
-
-