• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BD MEDICAL - DIABETES CARE BD MICRO-FINE¿ U-40 1ML, 29G X 12.7MM INSULIN SYRINGE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BD MEDICAL - DIABETES CARE BD MICRO-FINE¿ U-40 1ML, 29G X 12.7MM INSULIN SYRINGE Back to Search Results
Catalog Number 328504
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 03/28/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation and/or device history review, a supplemental report will be filed.
 
Event or Problem Description
It was reported that the needle of a bd micro-fine¿ u-40 1ml, 29g x 12.7mm insulin syringe was missing, and then found inside the barrel of the syringe.There was no report of exposure, injury or medical intervention.
 
Additional Manufacturer Narrative
Investigation results: investigation summary: customer returned (1) 1cc, 12.7mm, 29g relion syringe in an open poly bag from lot # 7177610.Customer states that the needle was missing on one of the syringes and the customer noticed the needle inside the barrel of the syringe next to the rubber stopper.The returned syringe was examined and exhibited a broken cannula.The broken end of the cannula was received in the barrel of the syringe.Microscopic examination of the returned sample revealed characteristics such as residual bends on the broken hub end as well as on the free end, cracked adhesive and tubing ovality (deformation from the normally circular cross section).When viewed together, these are all indicators of bending/re-straightening mode of failure.Removal of some of the adhesive made this observation more apparent.The shield was also examined for any possible scrapes or cuts related by cannula recapping or improper shielding, however nothing was observed.A review of the device history record was completed for batch # 7177610.All inspections and challenges were performed per the applicable operations qc specifications.There were five (5) notifications [2000704730, 200704784, 200704853, 200704729, 200704852] noted that did not pertain to the complaint.Severity: s_1__; occurrence: a complaint history check was performed and this is the 1st related complaint for needle missing and the 1st related complaint for foreign matter (needle in barrel) on lot # 7177610.Based on the samples / photo(s) received the investigation concluded: confirmed: bd was able to duplicate or confirm the customer¿s indicated failure (broken cannula and cannula in barrel) possible root causes include bending/re-straightening of the cannula by the customer and putting it in the barrel.Based on the above, no additional investigation and no capa is required at this time.Complaints received for this device and reported condition will continue to be tracked and trended.Information will be captured on trend reports and monitored monthly.Our business team regularly reviews the collected data for identification of emerging trends.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD MICRO-FINE¿ U-40 1ML, 29G X 12.7MM INSULIN SYRINGE
Common Device Name
INSULIN SYRINGE
Manufacturer (Section D)
BD MEDICAL - DIABETES CARE
1329 west highway 6
holdrege NE 68949
MDR Report Key7429618
Report Number1920898-2018-00243
Device Sequence Number1339573
Product Code FMF
UDI-Device Identifier00681131311625
UDI-Public00681131311625
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
K170386
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source consumer,other
Initial Reporter Occupation Patient
Type of Report Initial,Followup
Report Date (Section B) 04/26/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Catalogue Number328504
Device Lot Number7177610
Initial Date Received by Manufacturer 03/29/2018
Supplement Date Received by Manufacturer03/29/2018
Initial Report FDA Received Date04/13/2018
Supplement Report FDA Received Date04/26/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-