|
|
| Model Number |
9004 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Reocclusion (1985); Thrombosis (2100)
|
| Date of Event |
05/18/2018
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Analysis: the samples were not returned from the user facility; therefore, device evaluations are unable to be performed.A lot history review revealed there is no similar reocclusion complaints associated with this lot.A review of the device history record (dhr) indicates the lot was manufactured to specification.Conclusion: the actual samples were not received for evaluation.The dhr found nothing to indicate a manufacturing related cause for this event.The investigator assessed that the event was possibly related to the study device, to the procedure, and to the av access circuit.Based on the instructions for use (ifu), the occurrence of reocclusion is an inherent risk of any pta procedure, and has been reported in clinical trials of drug coated balloons.If additional information becomes known to the manufacturer, a supplemental report will be provided with all relevant information.The information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.
|
| |
|
Event or Problem Description
|
|
It was reported through a clinical registry that during the index procedure, two lutonix percutaneous transluminal drug coated balloon (dcb) dilatation catheters were used to treat the target lesions located in the cephalic vein outflow in the left upper arm.Approximately 4 months after the index procedure, the patient¿s target lesions were reportedly reoccluded.A revascularization via percutaneous angioplasty (pta) was performed and the hcp deemed it was successful.The investigator assessed that the event was possibly related to the study device, to the procedure, and to the av access circuit.The samples were discarded by the user facility and are not available for evaluation.No adverse patient effects were reported.This is one of two products involved with the reported event and the associated manufacturer¿s report number is 3006513822-2018-00088.
|
| |
|
Additional Manufacturer Narrative
|
|
Corrected data: the event date was changed from "(b)(6) 2018" to "(b)(6) 2018." the event description had the following sentence changed from "approximately 4 months after the index procedure, the patient¿s target lesions were reportedly reoccluded." to "approximately 6 months after the index procedure, the patient¿s target lesion was reportedly reoccluded." the relevant tests and lab data field was changed from "on (b)(6) 2018, reintervention via pta was performed on tl1 and tl2." to "on (b)(6) 2018, reintervention via pta was performed on tl2.On (b)(6) 2018, reintervention via pta was performed on tl1 and tl2." the samples were not returned from the user facility; therefore, device evaluations are unable to be performed.A lot history review revealed there is no similar reocclusion complaints associated with this lot.A review of the device history record (dhr) indicates the lot was manufactured to specification.Conclusion: the actual samples were not received for evaluation.The dhr found nothing to indicate a manufacturing related cause for this event.The investigator assessed that the event was possibly related to the study device, to the procedure, and to the av access circuit.Based on the instructions for use (ifu), the occurrence of reocclusion is an inherent risk of any pta procedure, and has been reported in clinical trials of drug coated balloons.If additional information becomes known to the manufacturer, a supplemental report will be provided with all relevant information.
|
| |
|
Event or Problem Description
|
|
It was reported through a clinical registry that during the index procedure, two lutonix percutaneous transluminal drug coated balloon (dcb) dilatation catheters were used to treat the target lesions located in the cephalic vein outflow in the left upper arm.Approximately 6 months after the index procedure, the patient¿s target lesion was reportedly reoccluded.A revascularization via percutaneous angioplasty (pta) was performed and the hcp deemed it was successful.The investigator assessed that the event was possibly related to the study device, to the procedure, and to the av access circuit.The samples were discarded by the user facility and are not available for evaluation.No adverse patient effects were reported.This is one of two products involved with the reported event and the associated manufacturer¿s report number is 3006513822-2018-00088.
|
| |
|
Event or Problem Description
|
|
It was reported through a clinical registry that during the index procedure, two lutonix percutaneous transluminal drug coated balloon (dcb) dilatation catheters were used to treat the target lesions located in the cephalic vein outflow in the left upper arm.Approximately 6 months after the index procedure, the patient¿s target lesion was reportedly reoccluded.A revascularization via percutaneous angioplasty (pta) was performed and the hcp deemed it was successful.Approximately 9 months after the index procedure, a thrombosis occurred at the access site.The hcp chose to abandon the access site and place a temporary catheter in the right arm.The investigator assessed that the reocclusion and thrombosis were possibly related to the study device and to the av access circuit, but definitely related to the index procedure.The samples were discarded by the user facility and are not available for evaluation.No adverse patient effects were reported.This is one of two products involved with the reported event and the associated manufacturer¿s report number is 3006513822-2018-00088.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information: the event problem code, 2100 - thrombosis, was added.Corrected data: the event description was changed from "it was reported through a clinical registry that during the index procedure, two lutonix percutaneous transluminal drug coated balloon (dcb) dilatation catheters were used to treat the target lesions located in the cephalic vein outflow in the left upper arm.Approximately 6 months after the index procedure, the patient¿s target lesion was reportedly reoccluded.A revascularization via percutaneous angioplasty (pta) was performed and the hcp deemed it was successful.The investigator assessed that the event was possibly related to the study device, to the procedure, and to the av access circuit.The samples were discarded by the user facility and are not available for evaluation.No adverse patient effects were reported.This is one of two products involved with the reported event and the associated manufacturer¿s report number is 3006513822-2018-00088." to "it was reported through a clinical registry that during the index procedure, two lutonix percutaneous transluminal drug coated balloon (dcb) dilatation catheters were used to treat the target lesions located in the cephalic vein outflow in the left upper arm.Approximately 6 months after the index procedure, the patient¿s target lesion was reportedly reoccluded.A revascularization via percutaneous angioplasty (pta) was performed and the hcp deemed it was successful.Approximately 9 months after the index procedure, a thrombosis occurred at the access site.The hcp choose to abandon the access site and place a temporary catheter in the right arm.The investigator assessed that the reocclusion and thrombosis were possibly related to the study device and to the av access circuit, but definitely related to the index procedure.The samples were discarded by the user facility and are not available for evaluation.No adverse patient effects were reported.This is one of two products involved with the reported event and the associated manufacturer¿s report number is 3006513822-2018-00088." the relevant tests and lab data field was changed from "on (b)(6) 2018, reintervention via pta was performed on tl2.On (b)(6) 2018, reintervention via pta was performed on tl1 and tl2." to "on (b)(6) 2018, reintervention via pta was performed on tl2.On (b)(6) 2018, reintervention via pta was performed on tl1 and tl2.On (b)(6) 2018, new access created in right arm with temporary catheter." the eval codes & desc codes were changed to align with fda guidance that became effective on july 6th, 2018.The following eval codes 3263 and 3317 were replaced with 4115, 3331, and 4110.The conclusion code 92 was replaced with 4310.The conclusion was changed to reflect the event of thrombosis and relatedness.The samples were not returned from the user facility; therefore, device evaluations are unable to be performed.A lot history review revealed there is no similar reocclusion complaints associated with this lot.A review of the device history record (dhr) indicates the lot was manufactured to specification.Conclusion: the actual samples were not received for evaluation.The dhr found nothing to indicate a manufacturing related cause for this event.The investigator assessed that the events were possibly related to the study devices and to the av access circuit, but definitely related to the index procedure.Based on the instructions for use (ifu), the occurrence of reocclusion and/or thrombosis are inherent risks of any pta procedure, and have been reported in clinical trials of drug coated balloons.If additional information becomes known to the manufacturer, a supplemental report will be provided with all relevant information.
|
| |
|
Search Alerts/Recalls
|
|
|