Model Number 04.037.028S
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Nonunion/Delayed-union Bone Fracture (2369)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Device was used for treatment, not diagnosis.Patient age, date of birth, gender, and weight not available for reporting.Date when non-union began is unknown.Device is not expected to return.Device history record review: manufacturing location: (b)(4), manufacturing date: 31-jul-2015, expiration date: 30-jun-2025.Part #: 04.037.028s, lot#: 9864913 (sterile) - 10 mm/125 deg ti cann tfna 380 mm/right- sterile.Quantity 6.Inspection sheet for in-process/inspect dimensional/final met inspection acceptance criteria.Component parts reviewed: the 04.037.912.2 - lock prong 125 degree, tfna bp-55 lot - 9529795.The 04.037.912.4 - wave spring, shim ended bp-55 lot - 7722133.The 4.037.912.3 - tfna lock drive bp-58 lot - 9841103.The 21127 - raw material lot bp-80 lot - 7813438.Raw material received from (b)(4).Certified test report received from (b)(4), certificate of test for titanium received from (b)(4) and raw material receiving/putaway checklist meet specification.No ncrs were generated during production.Review of the device history record(s) showed that there were no issues during the manufacture of the product that would contribute to this complaint condition.(b)(4), ethicon (abq), ¿sterility documentation was reviewed and determined to be conforming.¿ the investigation could not be completed; no conclusion could be drawn, as no product was received.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
It was reported that a patient underwent a right open reduction internal fixation (orif) of a proximal femur fracture using a trochanteric fixation nail - advance (tfna) on (b)(6) 2017.Postoperatively, a non-union was identified on a routine follow-up x-ray.Patient was asymptomatic (no complaints of pain or discomfort).The patient did not heal due to lateral cortex portion of the femur bone was missing because of the complex fracture pattern.The patient underwent a revision on (b)(6) 2018 and received a right total hip replacement.All the removed implants were intact.There were no issues during the revision and no surgical time delay.The patient status was stable.This is report 2 of 3 for (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
10MM/125 DEG TI CANN TFNA 380MM/RIGHT - STERILE
Common Device Name
ROD,FIXATION,INTRAMEDULLARY
Manufacturer (Section D)
WRIGHTS LANE SYNTHES USA PRODUCTS LLC
1302 wrights lane east
west chester PA 19380
MDR Report Key7440669
Report Number2939274-2018-51808
Device Sequence Number13766157
Product Code HSB
UDI-Device Identifier10886982095862
UDI-Public(01)10886982095862
Combination Product (Y/N)N
Initial Reporter StateWA
Initial Reporter CountryUS
PMA/510(K) Number
K131548
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2017
Device Explanted Year2018
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Health Professional
Type of Report Initial
Report Date (Section B) 03/29/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date06/30/2025
Device Model Number04.037.028S
Device Catalogue Number04.037.028S
Device Lot Number9864913
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 03/29/2018
Initial Report FDA Received Date04/18/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
-
-