Catalog Number 2C6700
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 03/19/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).The device was received and evaluation is in progress.Should additional relevant information become available, a supplemental report will be submitted.
 
Event or Problem Description
It was reported that an interlink blood set filter broke off during patient use.There was no report of a leak.There was no patient injury or medical intervention associated with this event.No additional information is available.
 
Additional Manufacturer Narrative
A partial device was received for evaluation.The tubing and male luer were received and the blood filter was missing.The male luer was functionally tested with no issues noted.The returned segment of the device was under-water tested for leaks and no issues were noted.Further testing could not be performed as the filter was not returned for evaluation.The reported condition of a broken off filter could not be further evaluated.The reported issue could neither be verified nor refuted from the sample received.A batch review was conducted and there were no deviations found related to this reported condition during the manufacture of this lot.Should additional relevant information become available, a supplemental report will be submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INTERLINK BLOOD RECIPIENT SET
Common Device Name
SET, BLOOD TRANSFUSION
Manufacturer (Section D)
BAXTER HEALTHCARE - CARTAGO
cartago
MDR Report Key7441451
Report Number1416980-2018-02247
Device Sequence Number11118251
Product Code BRZ
UDI-Device Identifier00085412068152
UDI-Public(01)00085412068152
Combination Product (Y/N)N
Initial Reporter StateIN
Initial Reporter CountryUS
PMA/510(K) Number
K993120
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 05/22/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Other
Device Expiration Date01/16/2023
Device Catalogue Number2C6700
Device Lot NumberR18A16095
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/09/2018
Initial Date Received by Manufacturer 03/26/2018
Supplement Date Received by Manufacturer05/14/2018
Initial Report FDA Received Date04/18/2018
Supplement Report FDA Received Date05/22/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-