Model Number G03785
Medical Device Problem Code Device Operates Differently Than Expected (2913)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 03/21/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).This report includes information known at this time.A follow up report will be submitted should additional relevant information become available.
 
Event or Problem Description
It was reported the wire guide in a turbo-ject standard power injectable picc (peripherally inserted central catheter) was unable to be removed from the peel-away.The wire guide resembled a pigtail.To date, additional information regarding the device and patient has not been made available.As reported, the patient did not experience any adverse effects or require any additional procedures due to this occurrence.
 
Additional Manufacturer Narrative
Investigation ¿ evaluation: a review of the dimensional verification, device history record, drawing, instructions for use (ifu), manufacturing instructions, quality control, specifications, and a visual inspection of the returned device were conducted during the investigation.The visual inspection of the returned device confirmed that the surface of the wire was in a damaged condition.The distal floppy tip appears to have been sheared off.The distal weld ball is missing.The coiling is missing from the distal tip.The sheared wire appears to have a pigtail shape.Also note, the proximal end of the wire appears to be in good condition.No damage was noted to the proximal end.No biological matter was visible on the damaged wire guide.No other damage was noted.Also of note, the dimensional length of the wire guide was noted.It was confirmed to be below tolerance however due to the damaged state it was received in, the wire guide was not out of specifications.Additionally, a document based investigation evaluation was performed.There is no evidence to suggest the product was not made to specifications.A review of the device history record showed no nonconforming events which could contribute to this failure mode.It should be noted there were no other reported complaints for this lot number.Based on the information provided, the examination of the returned product, and the results of our investigation, a definitive root cause could not be determined.We will continue to monitor for similar complaints.Per the quality engineering risk assessment, no further action is required.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TURBO-JECT STANDARD POWER INJECTABLE PICC LINE PICC
Common Device Name
LJS TURBO-JECT PERIPHERALLY INSERTED CENTRAL VENOUS CATHETER
Manufacturer (Section D)
COOK INC
750 daniels way
bloomington IN 47404
MDR Report Key7441509
Report Number1820334-2018-01003
Device Sequence Number1540151
Product Code LJS
UDI-Device Identifier00827002037854
UDI-Public(01)00827002037854(17)200119(10)8520869
Combination Product (Y/N)N
Initial Reporter CountryFR
PMA/510(K) Number
K111244
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 06/15/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberG03785
Device Catalogue NumberUPICS-5.0-CT-NT-1110
Was Device Available for Evaluation? Yes
Initial Date Received by Manufacturer 03/27/2018
Supplement Date Received by Manufacturer06/14/2018
Initial Report FDA Received Date04/18/2018
Supplement Report FDA Received Date06/15/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No