| Catalog Number |
D5981 |
| Medical Device Problem Code |
Tear, Rip or Hole in Device Packaging (2385)
|
| Health Effect - Clinical Code |
No Consequences Or Impact To Patient (2199)
|
| Date of Event |
03/23/2018
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
(b)(4).The actual device batch number associated with this event is not known.The international affiliate reports the following possible batch numbers: batch lcj143 mfg date: 03/20/2017, exp date: 02/28/2022; batch lpj095 mfg date: unk, exp date: unk.In addition, a review of the batch manufacturing records for the possible batch number lcj143 was conducted and the batches met all finished goods release criteria.Additional information was requested and the following was obtained: confirm the total qty of devices involved (same lot as reported) where the needle actually protruded from an unopened package causing hole, tear, or puncture that compromises sterility? one.Was the issue of all needles orientated vertically in the package noticed with new product or after the box had been previously opened and sitting in the storeroom or other location prior to use? the issue was noticed in the pacakges with new products.No further information will be provided.Please note- a limit of up to 10 eaches of unused representative samples only to be returned for evaluation.Attempts have been made to retrieve the device.To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.
|
| |
|
Event or Problem Description
|
|
It was reported that on (b)(6) 2018, a staff member of the hospital was pricked his/her finger on a needle which was protruded from an unopened package while he/she was working in the stock room.The injured staff was not infected.There were no adverse patient consequences.Additional information was requested.
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint # (b)(4) additional information: additional information: a review of the batch manufacturing records for the possible batch number lpj095 was conducted and the batches met all finished goods release criteria.Batch lpj095 mfg date: 12/21/2017 exp.Date - 11/30/2022 additional evaluation summary: an unopened sample of product code d5981, lot lcj143 was returned for evaluation.During the visual inspection of the sample, pin holes on the copolymer and top folder were observed, also needles were orientated vertically in the package this caused the holes on cavity.The manufacturing records were reviewed and the manufacturing/packaging criteria were met prior to the release of this batch.Based on the samples condition, the assignable cause suggests an incorrect needle park resulting in pinhole on package.An actual sample of lot lpj095 was returned for analysis.During the visual inspection of the opened sample, no damaged was observed on the package, also the needle-suture combinations were found partially dispensed and the needles in the folder were not observed orientated vertically in the package.The manufacturing records were reviewed and the manufacturing/packaging criteria were met prior to the release of this batch.Four unopened samples of product code d5981, lot lpj095 were returned for analysis.During the visual inspection of four unopened samples no damage was noted on the package.The samples were opened and contains four needle-suture combinations double armed.In two samples, no defects or needles orientated vertically were found; however, two samples had a needle orientated vertically in the package resulting in a parked incorrectly.The manufacturing records were reviewed and the manufacturing/packaging criteria were met prior to the release of this batch.According to the condition of the samples, the assignable cause suggests an incorrect needle park.
|
| |
|
Search Alerts/Recalls
|