Model Number 279718100
Medical Device Problem Code Break (1069)
Health Effect - Clinical Codes No Consequences Or Impact To Patient (2199); Not Applicable (3189)
Date of Event 03/26/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Device is available for evaluation.Investigation will be conducted.Follow up will be filed with the investigation results.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
It was reported screwdriver tip broke in the screw interface.When the surgeon tried to final tighten set screw on the rod, the set screw stripped and broke.We had to saw the head off the screw and then use a universal removal set and a reverse threaded driver to get the illiac screw out.
 
Additional Manufacturer Narrative
Product complaint # (b)(4).Investigation summary: one (1) exp 5.5 closed poly driver (product code: 279718100, lot # gm4275401) was returned for evaluation.Visual examination of the returned device found the distal tip of driver was fractured.Device was then sent for fracture analysis.Optical imaging of the fractured surface reveals plastic deformation at the hex-lobes and torsional shear markings following a circular pattern.The plastic deformation at the hex-lobes indicates a torsional overload.This suggests the driver underwent a quasi-static overload torsional shear failure.A review of the device history record was conducted.No issues were identified during the manufacturing and release of this product that could have contributed to the problem reported by the customer.All complaint trends will be evaluated as a part of the depuy spine monthly complaint review meeting.A definitive root cause for the tip of the expedium t20 closed polyaxial driver being broken cannot be determined.However, fracture analysis suggests that driver underwent a quasi-static overload torsional shear failure.As there has been no issue identified in the manufacturing or release of the device that could have contributed to the problem reported by the customer and no systemic trends were found, this complaint file will be closed with no further action required.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EXP 5.5 CLOSED POLY DRIVER
Common Device Name
SCREWDRIVER
Manufacturer (Section D)
MEDOS INTERNATIONAL SàRL CH
chemin-blanc 38
le locle 02400
SZ  02400
MDR Report Key7452114
Report Number1526439-2018-50397
Device Sequence Number1607791
Product Code HXX
UDI-Device Identifier10705034301389
UDI-Public(01)10705034301389
Combination Product (Y/N)N
Initial Reporter StateTN
Initial Reporter CountryUS
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,user f
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 03/26/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number279718100
Device Catalogue Number279718100
Device Lot NumberGM4275401
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/29/2018
Initial Date Received by Manufacturer 03/26/2018
Supplement Date Received by Manufacturer04/23/2018
Initial Report FDA Received Date04/23/2018
Supplement Report FDA Received Date05/02/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-