Model Number 661430
Health Effect - Clinical Code No Information (3190)
Date of Event 04/09/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Once the investigation has been completed any additional information will be reported in a supplemental report.
 
Event or Problem Description
While tightening the screw to the plate, the screw has passed though the oval hole on the plate.Noticed on x-ray check of screw position.Extra procedure time required to remove and reduce the fracture 45 mins.
 
Additional Manufacturer Narrative
Correction unk lot# the reported event that cortex screw axsos 3 ti ø3.5mm / l30mm was alleged of 'poor fixation' could be confirmed.Based on investigation, the root cause was attributed to be user related.The failure was caused by inadequate / excessive force during screw insertion.The device inspection revealed the following: the plate as such is slightly deformed.It is also clearly evident through the damages on the plate as well on the screw that far too much mechanical force has caused these damages.The screw had been forced through the plate hole, the damages on the screw and the plate clearly indicate that.Possibly encountered hard bone.A review of the device history was not possible because the lot number was not communicated.No corrective actions are required at this time.A review of the labeling did not indicate any abnormalities.No indications of material, manufacturing or design related problems were found during the investigation.If any further information is provided, the investigation report will be updated.
 
Event or Problem Description
While tightening the screw to the plate, the screw has passed though the oval hole on the plate.Noticed on x-ray check of screw position.Extra procedure time required to remove and reduce the fracture 45mins.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CORTEX SCREW AXSOS 3 TI Ø3.5MM / L30MM
Common Device Name
PLATE, FIXATION, BONE
Manufacturer (Section D)
STRYKER GMBH
bohnackerweg 1
postfach
selzach 2545
CH  2545
MDR Report Key7475052
Report Number0008031020-2018-00332
Device Sequence Number13536676
Product Code HRS
UDI-Device Identifier07613252580362
UDI-Public(01)07613252580362
Combination Product (Y/N)N
Initial Reporter CountryAU
PMA/510(K) Number
K123964
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source health professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 08/08/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number661430
Device Catalogue Number661430
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer05/30/2018
Initial Date Received by Manufacturer 04/09/2018
Supplement Date Received by Manufacturer07/12/2018
Initial Report FDA Received Date05/01/2018
Supplement Report FDA Received Date08/08/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient Age44 YR
-
-