|
Device is an instrument and is not implanted/explanted.Complainant part is expected to be returned for manufacturer review/investigation, but has yet to be received.(b)(6) without a lot number the device history records review could not be completed.The investigation could not be completed; no conclusion could be drawn, as no product was received.The investigation could not be completed; no conclusion could be drawn, as no product was received.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
The subject device has been received by the manufacturer and is undergoing investigation.The results of the investigation are pending completion and will be submitted in a supplemental report.Device used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Additional narrative: lot number.Date rec'd by mfr: the date was inadvertently left blank on medwatch follow-up 1.Device used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.A device history record review was performed for the subject device: part: 399.430 , lot: 9856770 , manufacturing site: umkirch , release to warehouse date: 12.Apr.2016.The device history record shows this lot of (b)(4) pieces was processed through the normal manufacturing and inspection operations with no rework or nonconformities noted.This lot met all dimensional, visual and functional criteria at the time of release with no issues documented during the manufacturing process.Review of the device history record showed that there were no issues during the manufacture of this product which would contribute to this complaint condition.A product development investigation was performed for the subject device: device evaluation: investigation flow: the ¿visual (appearance not as expected)¿ flow was completed for the complaint of residue.The ¿damage: visual (appearance not as expected)¿ was also completed based on the deformation observed on the head of the hammer.Visual inspection: the hammer was received intact with significant surface wear consistent with heavy forceful use over its approximately 2 year lifespan.Small scratches and nicks were observed over the length of the device.Additionally, the outer edges of the flat of the mallet portion showed deformed edges such that the edge had been flatted and bent away from the impact surface.No residue was observed on the device.Thus, based on the received condition, the reported residue on the device could not be confirmed and the received condition does not agree with the complaint description.However, additional damage in the form of bent/warped edges of the mallet were noted.Thus, the overall complaint condition is confirmed.Document/specification review: the following drawings, reflecting the current under review drawing and manufactured revision, were reviewed.Hammer 700 grams: 399_43 , head, hammer 700 grams (component): 399_43_1, handle, hammer 700 grams (component): 399_43_3.During the investigation no product design issues or discrepancies were observed that may have contributed to the complaint condition.Dimensional inspection: dimensional inspection for the condition of residue is not applicable based on the condition and that the determination of no observed residue is conclusive.Inspection could be performed for the bent/warped condition of the mallet head.Inspection of the outer diameter of the hammer head adjacent to the damage measured 40.12mm which is within the specification of 40mm +/-0.8 per drawing 399_43_3.Measured using calipers ca592.Conclusion: the reported condition of residue on the device could not be confirmed as no residue was observed.However, additional damage in the form of bent/warped edges of the mallet were noted.Thus, the overall complaint condition is confirmed.No definitive root cause was able to be determined as the circumstances surrounding the event are unknown.However, the condition is consistent with forceful impact on the edge of the mallet.No design or manufacturing defect or deficiency was observed during the investigation.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.Device used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|