MAUDE Adverse Event Report: BARD ACCESS SYSTEMS POWERPICC 5F DUAL-LUMEN POLYURETHANE CATHETER RADIOLOGY BASIC TRAY (70 CM GW); CATHETER,INTRAVASCULAR,THERAPEUTIC,LONG-TERM GREATER THAN 30 DAYS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BARD ACCESS SYSTEMS POWERPICC 5F DUAL-LUMEN POLYURETHANE CATHETER RADIOLOGY BASIC TRAY (70 CM GW); CATHETER,INTRAVASCULAR,THERAPEUTIC,LONG-TERM GREATER THAN 30 DAYS Back to Search Results
Model Number 3275155
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
The information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.The manufacturer has received the sample and will evaluate.Results are expected soon.A lot history review (lhr) of recp1872 showed no other similar product complaint(s) from this lot number.
 
Event or Problem Description
It was reported that the facility had a picc wire that came unraveled and broke in two pieces during placement.The broken wire parts were retrieved by doctors using a snare.
 
Additional Manufacturer Narrative
The following were reviewed as part of this investigation: patient severity, frequency analysis, applicable previous investigation(s), sample (if available), applicable fmea documents, labeling, and applicable manufacture records.Based on a review of this information, the following was concluded: the complaint of broken guidewire is confirmed and was determined to be use related.One guidewire was returned for evaluation.An initial visual observation showed the coiled wire and core wire of the guidewire were broken about 4.7 cm distal to the beginning of the coiled wire.The coiled wire was also observed to be unraveled from beginning of the coiled to the distal end.The weld tip was observed to be missing.A microscopic observation revealed use residue on the returned sample.The fracture surfaces of the coiled wire were observed to be jagged and granular in texture.The fracture site of the core wire was observed to be tapered and its surface was observed to be granular in texture, which is evidence of tensile failure.The product ifu states: ¿if the guidewire must be withdrawn while the needle is inserted, remove both the needle and wire as a unit to prevent the needle from damaging or shearing the guidewire.¿ no further action is required because the reported event could not be related to a deficiency in product manufacture or deficiency while under correct product use.A lot history review (lhr) of recp1872 showed no other similar product complaint(s) from this lot number.
 
Event or Problem Description
It was reported that the facility had a picc wire that came unraveled and broke in two pieces during placement.The broken wire parts were retrieved by doctors using a snare.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
POWERPICC 5F DUAL-LUMEN POLYURETHANE CATHETER RADIOLOGY BASIC TRAY (70 CM GW)
Common Device Name
CATHETER,INTRAVASCULAR,THERAPEUTIC,LONG-TERM GREATER THAN 30 DAYS
Manufacturer (Section D)
BARD ACCESS SYSTEMS
605 n. 5600 w.
salt lake city UT 84116
MDR Report Key7498698
Report Number3006260740-2018-00919
Device Sequence Number1314733
Product Code LJS
UDI-Device Identifier00801741027932
UDI-Public(01)00801741027932
Combination Product (Y/N)N
Initial Reporter StateIL
Initial Reporter CountryUS
PMA/510(K) Number
K051672
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Health Professional
Type of Report Initial,Followup
Report Date (Section B) 05/23/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model Number3275155
Device Catalogue Number3275155
Device Lot NumberRECP1872
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer05/03/2018
Event Location Hospital
Initial Date Received by Manufacturer 05/03/2018
Supplement Date Received by Manufacturer05/09/2018
Initial Report FDA Received Date05/09/2018
Supplement Report FDA Received Date05/23/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
-
-