Catalog Number 802002
Medical Device Problem Code Restricted Flow rate (1248)
Health Effect - Clinical Codes No Consequences Or Impact To Patient (2199); No Known Impact Or Consequence To Patient (2692)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.The information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.The device was not returned.
 
Event or Problem Description
It was reported that urine stopped flowing into the drain bag when the bag was partially full.The patient reported that the urine backed up within the tubing.
 
Additional Manufacturer Narrative
The device was not returned for evaluation.The device history record was reviewed and found nothing that could have caused or contributed to the reported event.The instructions for use state the following: ¿bardia closed system urinary drainage bag with anti-reflux chamber and flexible strap contents: 2000ml (approx.Vol.)/urine sample sleeve ¿ 0.313¿ i.D.(7.95mm) drainage tube ¿ round profile center entry ¿ anti-reflux chamber ¿ flexible hook & loop cloth strap ¿ draw-off tube with clamp caution: federal (u.S.A.) law restricts this device to sale by or on the order of a physician.Directions for use: 1.Wash hands.2.Remove protective cap from drainage tube and connect drainage tube adapter to catheter.3.Fasten drainage bag to bedframe near the foot of the bed.Do not allow bag to touch floor.Important: hang drainage tube in a straight fashion from bedside to drainage bag.If drainage bag is placed even with patient¿s hip, coil tubing alongside patient.Tubing should be draped over patient¿s leg.4.Check that urine is draining into bag.5.To empty bag: a.Remove outlet tube from housing.B.Release clamp and empty bag.C.When bag is empty, return clamp to closed position and replace tube in housing.Note: if specimen is required, see directions for obtaining urine sample.6.Wash hands.7.After use, this product may be a potential biohazard.Handle and dispose of in accordance with accepted medical practice and applicable local, state and federal laws and regulations.Directions for obtaining urine sample: 1.Kink tubing a minimum of 3 inches below sample sleeve until urine is under sample site.2.Swab surface of puncture site with antiseptic wipe.3.Insert needle (21g or smaller) through center of puncture site.Be careful to avoid puncturing opposite side of sample sleeve.4.Remove desired volume of urine.Release kink to permit flow to drainage bag.5.Send specimen to laboratory.".
 
Event or Problem Description
It was reported that urine stopped flowing into the drain bag when the bag was partially full.The patient reported that the urine backed up within the tubing.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BARDIA® CLOSED SYSTEM URINARY DRAINAGE BAG WITH ANTI-REFLUX CHAMBER AND STRAP
Common Device Name
DRAIN BAG
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington GA 30014
MDR Report Key7516430
Report Number1018233-2018-01763
Device Sequence Number1696410
Product Code KNX
UDI-Device Identifier00801741040757
UDI-Public(01)00801741040757
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source consumer,distributor,other
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 06/08/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Expiration Date07/31/2022
Device Catalogue Number802002
Device Lot NumberNGBU1144
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 04/24/2018
Supplement Date Received by Manufacturer06/01/2018
Initial Report FDA Received Date05/15/2018
Supplement Report FDA Received Date06/08/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-