Model Number H7493808015450
Medical Device Problem Code Material Rupture (1546)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 04/20/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).
 
Event or Problem Description
It was reported that balloon rupture occurred.The target lesion was located in the left anterior descending artery.A 4.5mm x 15mm quantum¿ maverick¿ balloon catheter was advanced for dilation.However, after the second inflation at 18 atmospheres, the balloon ruptured.The device was completely removed with the guide catheter and the procedure was completed with another of the same device.No patient complications were reported and the patient's status was stable.
 
Additional Manufacturer Narrative
Device evaluated by mfr: returned product consisted of a quantum maverick mr balloon catheter.The balloon was loosely folded with blood in the balloon, wire and inflation lumen.Microscopic inspection revealed a burst in the balloon material, 11mm in length.Inspection of the remainder of the device revealed a kink in the hypotube located 20cm from the strain relief.The investigation conclusion is operational context as the product meets the design & manufacture specification but due to anatomical/procedural factors encountered during the procedure, performance was limited.(b)(4).
 
Event or Problem Description
It was reported that balloon rupture occurred.The target lesion was located in the left anterior descending artery.A 4.5mm x 15mm quantum maverick balloon catheter was advanced for dilation.However, after the second inflation at 18 atmospheres, the balloon ruptured.The device was completely removed with the guide catheter and the procedure was completed with another of the same device.No patient complications were reported and the patient's status was stable.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
QUANTUM¿ MAVERICK¿
Common Device Name
CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS
Manufacturer (Section D)
BOSTON SCIENTIFIC - MAPLE GROVE
one scimed place
maple grove MN 55311
MDR Report Key7524575
Report Number2134265-2018-04338
Device Sequence Number19239127
Product Code LOX
UDI-Device Identifier08714729392835
UDI-Public08714729392835
Combination Product (Y/N)N
Initial Reporter CountryCN
PMA/510(K) Number
P860019
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,distri
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 04/25/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date08/30/2020
Device Model NumberH7493808015450
Device Catalogue Number38080-1545
Device Lot Number21082726
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer05/07/2018
Initial Date Received by Manufacturer 04/25/2018
Supplement Date Received by Manufacturer06/01/2018
Initial Report FDA Received Date05/17/2018
Supplement Report FDA Received Date06/20/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-