Catalog Number 03.010.405
Medical Device Problem Code Device Operational Issue (2914)
Health Effect - Clinical Code No Patient Involvement (2645)
Date of Event 03/28/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Device used for treatment, not diagnosis.Patient id: (b)(6).Patient age not provided for reporting.Device is an instrument and is not implanted/explanted.(b)(6).The device was received, the investigation could not be completed, and no conclusion could be drawn, as product is entering the complaint system.Device used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
Device report from synthes on an event in (b)(6) as follows: it was reported that the removal of the proximal femoral antirotation nail (pfna) from the connecting screw was not possible.The surgery was delayed about 60 minutes.Devices had to be removed.Surgery was completed with new products.Surgery took four hours.This report is 1 of 2 for (b)(4).
 
Additional Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Part number: 03.010.405.Synthes lot number: 8365826.Release to warehouse date: 20.June 2013.Manufacturing site: (b)(4).No ncrs were generated during production.Review of the device history record(s) showed that there were no issues during the manufacture of the product that would contribute to this complaint condition.Customer quality conducted an investigation of the returned device.Investigation selection.Investigation site: cq zuchwil.Selected flow: 2.Device interaction/functional.Visual inspection: the returned pfna nail was tightened with the connecting screw on the insertion handle.No abnormal findings were identified on these returned parts.All in all the parts are in used condition.Function test: the returned assembled pfna nail on the insertion handle could be dissolved without high effort.With the screwdriver (art.03.023.011) could dissolved the connecting screw (art.357.029).Summary: the received condition of these parts are concordant with the complaint description and the complaint condition is unconfirmed.With the screwdriver (art.03.023.011) could dissolved the connecting screw (art.357.029).No abnormal findings were identified on these returned parts.All in all the parts are in used condition.Based on that and the condition of the parts a product related issue can be excluded.Unfortunately the exact cause which has led to the occurence could not be evaluated.We only can assume that a mechanical overloading situation, for example strongly tighten during assembling the construct, has caused the stuck connection based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed as no product related issue could be detected.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
Concomitnat device reported: pfna blade (04.027.036s, lot l700651, quantity 1).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RADIOLUCENT INSERTION HANDLE F/TROCHANTERIC FIXATION NAILS
Common Device Name
MISC ORTHO SURGICAL INSTRUMENT
Manufacturer (Section D)
OBERDORF SYNTHES PRODUKTIONS GMBH
eimattstrasse 3
oberdorf 4436
SZ  4436
MDR Report Key7535544
Report Number8030965-2018-53925
Device Sequence Number1652793
Product Code LXH
UDI-Device Identifier07611819349421
UDI-Public(01)07611819349421
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Health Professional
Type of Report Initial,Followup
Report Date (Section B) 05/02/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number03.010.405
Device Lot Number8365826
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer05/18/2018
Initial Date Received by Manufacturer 05/02/2018
Supplement Date Received by Manufacturer07/18/2018
Initial Report FDA Received Date05/22/2018
Supplement Report FDA Received Date07/25/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age83 YR
Patient Weight80
-
-