• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: OMNILIFE SCIENCE, INC. OMNI HIP SYSTEM; PROSTHESIS, HIP, SEMI-CONSTRAINED

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

OMNILIFE SCIENCE, INC. OMNI HIP SYSTEM; PROSTHESIS, HIP, SEMI-CONSTRAINED Back to Search Results
Catalog Number HC-21002-HA
Health Effect - Clinical Code Reaction (2414)
Date of Event 09/27/2016
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
The complainant made no indication of any omnilife science device malfunction or deficiency related to the identity, quality, durability, reliability, safety, effectiveness or device performance contributing to the adverse event.Review of the manufacturing documentation and sterilization documentation for the devices in question revealed no deviation from process or non-conformity of product that would have caused or contributed to the adverse event.
 
Event or Problem Description
The complaint involved a patient who underwent a hip revision surgery on (b)(6) 2016.The original surgery is dated (b)(6) 2015.The revision surgery occurred because of metallosis.During the revision, the original omni size 2 ha coated arc stem, arc anteverted neck, 28 mm +3.5 biolox delta ceramic femoral head, and serf's ci 53/28 e liner were removed and replaced with a size 4 lat k1 porous femoral stem, 28 mm +0 biolox delta femoral head, and a serf liner of the same size.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
OMNI HIP SYSTEM
Common Device Name
PROSTHESIS, HIP, SEMI-CONSTRAINED
Manufacturer (Section D)
OMNILIFE SCIENCE, INC.
480 paramount drive
raynham MA 02767
MDR Report Key7545018
Report Number1226188-2018-00067
Device Sequence Number18883288
Product Code LPH
UDI-Device Identifier00841690115793
UDI-Public00841690115793
Combination Product (Y/N)N
Initial Reporter StateMA
Initial Reporter CountryUS
PMA/510(K) Number
K090845
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2015
Device Explanted Year2016
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 04/30/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date11/30/2019
Device Catalogue NumberHC-21002-HA
Device Lot Number19093
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 04/30/2018
Initial Report FDA Received Date05/25/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization; Required Intervention;
Patient Age50 YR
-
-