• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: RADIOMETER MEDICAL APS SAFEPICO70

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

RADIOMETER MEDICAL APS SAFEPICO70 Back to Search Results
Model Number 956-616
Medical Device Problem Codes Fluid/Blood Leak (1250); Fracture (1260)
Health Effect - Clinical Code No Patient Involvement (2645)
Date of Event 03/01/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Date of event is best guess.
 
Event or Problem Description
According to the complaint, blood sprayed out from the syringe.The blood hit the user.However, the blood hit the shirt in the area of the chest region.The customer reported that there is a crack on the body of the syringe allowing flow of blood.
 
Additional Manufacturer Narrative
Investigation has identified that the root cause is a manufacturing error related to the labelling assembly in the production.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SAFEPICO70
Common Device Name
SAFEPICO70
Manufacturer (Section D)
RADIOMETER MEDICAL APS
aakandevej 21
broenshoej, 2700
DA  2700
MDR Report Key7547375
Report Number3002807968-2018-00038
Device Sequence Number14056778
Product Code JKA
UDI-Device Identifier05700699566164
UDI-Public(01)05700699566164(17)191021(10)YV55
Combination Product (Y/N)N
Initial Reporter CountryFR
PMA/510(K) Number
K043143
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 06/14/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Nurse
Device Expiration Date10/21/2019
Device Model Number956-616
Device Catalogue Number956-616
Device Lot NumberYV-55
Was the Report Sent to FDA? No
Initial Date Received by Manufacturer 05/04/2018
Supplement Date Received by Manufacturer05/17/2018
Initial Report FDA Received Date05/28/2018
Supplement Report FDA Received Date06/14/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-