| Model Number |
M00546270 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Hemorrhage/Blood Loss/Bleeding (1888); Pain (1994)
|
| Date of Event |
05/01/2018
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Patient's exact age is unknown; however it was reported that the patient was over the age of 18.The complainant was unable to report the lot number; therefore the manufacture date and expiration date are unknown.However, the complainant stated that the device was used prior to the expiration date.According to the complainant, the suspect device has been disposed and is not available for return.If any further relevant information is received, a supplemental mdr will be filed.
|
| |
|
Event or Problem Description
|
|
Note: this report pertains to one of two devices used during the same procedure.Refer to manufacturer report# 3005099803-2018-01800 for the spyscope digital access and delivery catheter, and 3005099803-2018-01801 for the spybite¿ biopsy forceps.It was reported to boston scientific corporation that a spyscope digital access & delivery catheter and a spybite¿ were used in the common bile duct (cbd) during a bile duct biopsy procedure performed on (b)(6) 2018.According to the complainant, they performed bile duct biopsy using these devices.On (b)(6) 2018, an endoscopy confirmed that the patient was bleeding and afterwards the patient experienced severe pain.A non-bsc covered stent was used to stop the bleeding but it perforated the bile duct, and part of the stent protruded into the abdominal cavity.The bleeding was not stopped.They used a hardener and a metal coil during angiography and the bleeding was stopped.The stent remained inside the patient and an endoscopic removal procedure is planned.In the physician's assessment, the patient had liver cirrhosis and then during use, the devices scrubbed the bile duct near duodenal papilla.Aneurysm had developed and bleeding occurred.There were no reported malfunction of the spyscope ds and spybite¿.The patient's condition after this procedure was reported to be stable.
|
| |
|
Event or Problem Description
|
|
Note: this report pertains to one of two devices used during the same procedure.Refer to manufacturer report# 3005099803-2018-01800 for the spyscope digital access.It was reported to boston scientific corporation that a spyscope digital access & delivery catheter and a spybite¿ were used in the common bile duct (cbd) during a bile duct biopsy procedure performed (b)(6) 2018.According to the complainant, they performed bile duct biopsy using these devices.On may 1, 2018, an endoscopy confirmed that the patient was bleeding and afterwards the patient experienced severe pain.A non-bsc covered stent was used to stop the bleeding but it perforated the bile duct, and part of the stent protruded into the abdominal cavity.The bleeding was not stopped.They used a hardener and a metal coil during angiography and the bleeding was stopped.The stent remained inside the patient and an endoscopic removal procedure is planned.In the physician's assessment, the patient had liver cirrhosis and then during use, the devices scrubbed the bile duct near duodenal papilla.Aneurysm had developed and bleeding occurred.There were no reported malfunction of the spyscope ds and spybite¿.The patient's condition after this procedure was reported to be stable.Additional information received on june 4, 2018.The location of the bleeding was reported to be in the bile duct, which was related to the location of the perforation.It is unknown if the patient was on anticoagulants, however, it was reported that the patient has a tendency to bleed easily because the patient has liver cirrhosis.There were no reported defects of the spyscope ds that may have contributed to the event.
|
| |
|
Search Alerts/Recalls
|
|
|