MAUDE Adverse Event Report: BOSTON SCIENTIFIC - GALWAY SYNERGY II EVEROLIMUS-ELUTING PLATINUM CHROMIUM CORONARY STENT SYSTEM; BIODEGRADABLE POLYMER DRUG ELUTING CORONARY STENT SYSTEM

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC - GALWAY SYNERGY II EVEROLIMUS-ELUTING PLATINUM CHROMIUM CORONARY STENT SYSTEM; BIODEGRADABLE POLYMER DRUG ELUTING CORONARY STENT SYSTEM Back to Search Results
Model Number H7493926012250
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 05/04/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Device is a combination product.(b)(4).
 
Event or Problem Description
It was reported that shaft break occurred.The 80% stenosed target lesion was located in the moderately tortuous mid circumflex artery.A 2.50 x 12 synergy ii drug-eluting stent was advanced for treatment.Upon insertion, the physician noted that they had slightly kinked the catheter shaft and attempted to straighten the shaft.The device was inserted and as it entered into the target vessel, the hypotube of the catheter fractured separating itself from the proximal portion of the catheter.The device was completely removed from the patient's body and the procedure was completed with another of the same device.No patient complications were reported and the patient's status was excellent.
 
Additional Manufacturer Narrative
Device evaluated by mfr: the stent delivery system (sds) was returned for analysis.A visual examination of the stent found no issues.There was no sign of damage, stretching or lifting of the stent struts.The stent showed no signs of movement and was set equidistant between the proximal and distal markerbands.The crimped stent outer diameter (od) was measured and is within maximum crimped stent profile measurement.The balloon cones were reviewed and no issues were noted.The balloon wings were tightly wrapped and evenly folded and were not subjected to positive pressure.A visual and microscopic examination of the bumper tip showed no signs of damage.A visual and tactile examination of the hypotube found a hypotube break 495 mm distal from the distal end of the strain relief.Multiple hypotube kinks were also noted along the entire length of the catheter.This type of damages is consistent with excessive force being applied to the delivery system.A visual and tactile examination of the shaft polymer extrusion found an inner/outer shaft polymer extrusion kink 44 mm distal to the port bond.A midshaft kink was also noted 110 mm proximal to the port bond.No other issues were identified during the product analysis.The manufacturing batch record review confirmed that the device met all material, assembly and performance specifications.The investigation conclusion is user / use error as there was an act or omission of an act that resulted in a different medical device response than intended by the manufacturer or expected by the user.The most probable root cause has been determined to be use/user error as the direction for use states: "at any time during use of the monorail stent delivery system, if the proximal shaft (hypotube) has been bent or kinked, do not continue to use the catheter¿.(b)(4).
 
Event or Problem Description
It was reported that shaft break occurred.The 80% stenosed target lesion was located in the moderately tortuous mid circumflex artery.A 2.50 x 12 synergy ii drug-eluting stent was advanced for treatment.Upon insertion, the physician noted that they had slightly kinked the catheter shaft and attempted to straighten the shaft.The device was inserted and as it entered into the target vessel, the hypotube of the catheter fractured separating itself from the proximal portion of the catheter.The device was completely removed from the patient's body and the procedure was completed with another of the same device.No patient complications were reported and the patient's status was excellent.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SYNERGY II EVEROLIMUS-ELUTING PLATINUM CHROMIUM CORONARY STENT SYSTEM
Common Device Name
BIODEGRADABLE POLYMER DRUG ELUTING CORONARY STENT SYSTEM
Manufacturer (Section D)
BOSTON SCIENTIFIC - GALWAY
MDR Report Key7550559
Report Number2134265-2018-04700
Device Sequence Number274789
Product Code NIQ
UDI-Device Identifier08714729840039
UDI-Public08714729840039
Combination Product (Y/N)N
Initial Reporter StateMN
Initial Reporter CountryUS
PMA/510(K) Number
P150003
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 05/04/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date12/20/2018
Device Model NumberH7493926012250
Device Catalogue Number39260-1225
Device Lot Number0021567534
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer05/23/2018
Initial Date Received by Manufacturer 05/04/2018
Supplement Date Received by Manufacturer06/15/2018
Initial Report FDA Received Date05/29/2018
Supplement Report FDA Received Date07/10/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-