CORDIS CORPORATION POWERFLEXPRO 12MM6CM 135; CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL
|
Back to Search Results |
|
| Model Number |
4401206X |
| Medical Device Problem Code |
Leak/Splash (1354)
|
| Health Effect - Clinical Code |
No Consequences Or Impact To Patient (2199)
|
| Date of Event |
05/07/2018
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
It was reported that the 12x60mm 135cm powerflex pro balloon catheter (bc) transfer rod connector leaked.There was no patient injury.The device was not returned for analysis.A device history record (dhr) review of lot 17712978 revealed no anomalies or non-conformances during the manufacturing and inspection processes that can be associated with the reported event.The reported ¿pta/ptca system leakage¿ could not be confirmed as the device was not returned for analysis.The exact cause of the leakage could not be determined.Based on the limited information available for review, it is not possible to determine what may have contributed to the reported event; however, procedural/handling factors are possible.According to the instructions for use, ¿prior to angioplasty, the catheter should be examined to verify functionality and integrity, and ensure that its size and shape are suitable for the specific procedure for which it is to be used.Do not use if product damage is suspected or evident.If resistance is met during manipulation, determine the cause of resistance before proceeding.¿ the ifu also states, ¿attach a 3-way stopcock to the inflation port, which is marked ¿balloon.¿ attach a partially filled syringe with heparinized saline to the stopcock, open the stopcock to the balloon and induce negative pressure.Hold the syringe and proximal end of the catheter above the distal end of the catheter, and hold the balloon vertically with the balloon tip pointing down.While maintaining negative pressure close the stopcock to the inflation port.Remove the syringe and purge the air.To ensure air contained in the balloon and inflation lumen is removed, apply negative pressure twice as instructed and repeat steps 2-4.Without twisting, slide the forming tube off the balloon.Prepare an angioplasty inflation system with a 50% solution of contrast medium in sterile saline or similar solution.Purge the air from the inflation device.Connect the inflation device to the 3-way stopcock that is connected to the catheter inflation port, open the stopcock to the catheter and slowly fill the inflation lumen and the balloon will slowly fill with diluted contrast medium.¿ neither the dhr nor the information available suggests a design or manufacturing related cause for the reported event; therefore, no corrective/preventive action will be taken.
|
| |
|
Event or Problem Description
|
|
It was reported that the powerflex pro balloon catheter transfer rod connector leaked.There was no patient injury.
|
| |
|
Additional Manufacturer Narrative
|
|
It was reported that the powerflex pro balloon catheter transfer rod connector leaked.Additional information was received and the shaft of the powerflex pro was leaking.There was no patient injury.A non-sterile powerflexpro 12mm6cm 135 was received coiled inside a plastic bag.The balloon was received not inflated.Per visual analysis, an external damage could be observed on the strain relief of the unit.No other anomalies were observed.Per functional analysis; pressurized water was applied to the catheter using a lab sample inflator/deflator and a leakage was observed near the hub.During the microscopic analysis of the unit, a "weakness" was observed at the union of the hub with the shaft.The shaft appeared as damaged near the hub, having appearance of external damage.This damage can be a possible contributor to the observed leakage.The unit was sent to sem analysis to determine the possible causes of this damage.The images shows a hole in the strain relief.No tool marks or mechanical damages could be confirmed.The damage cannot be concluded as an over-mold process fail since the material rupture resembles a burst, and lot testing found that the lot was in specification.The manufacturing process of the powerflex pro catheters was analyzed to determine the implemented controls for detection of the failure described on this complaint.After sem images were reviewed, it cannot be concluded that complaint failures are manufacturing-related.A device history record (dhr) review of lot 17712978 revealed no anomalies during the manufacturing and inspection processes that can be associated with the reported complaint.The reported ¿body/shaft leakage¿ was confirmed through analysis of the returned device.However, the exact cause of this failure could not be conclusively determined during the analysis.Based on the limited information available for review and the product analysis, external agents in contact with the strain relief and/or applied force used during handling may have contributed to the damage noted to the strain relief.According to the instructions for use, ¿prior to angioplasty, the catheter should be examined to verify functionality and integrity, and ensure that its size and shape are suitable for the specific procedure for which it is to be used.Do not use if product damage is suspected or evident.If resistance is met during manipulation, determine the cause of resistance before proceeding.¿ the ifu also states, ¿attach a 3-way stopcock to the inflation port, which is marked ¿balloon.¿ attach a partially filled syringe with heparinized saline to the stopcock, open the stopcock to the balloon and induce negative pressure.Hold the syringe and proximal end of the catheter above the distal end of the catheter, and hold the balloon vertically with the balloon tip pointing down.While maintaining negative pressure close the stopcock to the inflation port.Remove the syringe and purge the air.To ensure air contained in the balloon and inflation lumen is removed, apply negative pressure twice as instructed and repeat steps 2-4.Without twisting, slide the forming tube off the balloon.Prepare an angioplasty inflation system with a 50% solution of contrast medium in sterile saline or similar solution.Purge the air from the inflation device.Connect the inflation device to the 3-way stopcock that is connected to the catheter inflation port, open the stopcock to the catheter and slowly fill the inflation lumen and the balloon will slowly fill with diluted contrast medium.¿ neither the dhr review nor the product analysis suggests that the reported failure could be related to the manufacturing process of the unit.Therefore, no corrective actions will be taken at this time.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information was received and section d10 and h6 was updated.The shaft of the powerflex pro was leaking.Therefore, malfunction code pta/ptca system - leakage was removed and catheter body/shaft - leakage was added.This device was received for analysis but the engineering report is not yet available.However, it will be submitted within 30 days upon receipt.
|
| |
|
Additional Manufacturer Narrative
|
|
Device history record (dhr) review was conducted and the product met quality requirements for product acceptance.Additional information is pending and will be submitted within 30 days upon receipt.
|
| |
|