SMITH & NEPHEW, INC. GEN II CEMENTED TIBIAL B/PLATE SZ 8 LEFT; PRSTHSS,KNEE,PATELLOFEMOROTIBIAL,SM-CNSTRND,CEMENTED,POLYMER/METAL/POLYMER
|
Back to Search Results |
|
| Catalog Number |
71420174 |
| Medical Device Problem Code |
Appropriate Device Problem Term/Code Not Available (3191)
|
| Health Effect - Clinical Code |
Injury (2348)
|
| Date of Event |
04/04/2017
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported that patient had a legion/genesis knee implant on (b)(6) 2015 and underwent a revision surgery on (b)(6) 2017 due to instability and left knee giving away, pain, swelling, accompanied by warmth, erythema and fevers.
|
| |
|
Additional Manufacturer Narrative
|
|
The associated complaint devices were not returned.A clinical evaluation was conducted and no relevant supporting clinical information has been provided to assist with a clinical investigation, and there is no report of the patient's current condition.Therefore based on insufficient information, a clinical assessment cannot be performed at this time.A review of complaint history on the listed parts revealed no prior complaint for the listed batches with the same failure mode.A review of the manufacturing records did not reveal a manufacturing abnormality that could have caused or contributed to the reported incident.Without the actual product involved and/or device information, our investigation cannot proceed.If the device or new information is received in the future, this complaint can be re-opened.No further actions are being taken at this time.We consider this investigation closed.
|
| |
|
Additional Manufacturer Narrative
|
|
The associated genesis ii cemented tibial baseplate, legion dished insert and legion cr oxinium femoral component were returned and evaluated.The genesis ii resurfacing patella component was not returned.A lab analysis conducted during this investigation indicated that the femoral component showed damage on the articular surface, and scratching was observed around the medial and lateral sides of the part.Cement adhesion was visible on the femoral component¿s interface, including the pegs.The insert showed some burnishing and/or wear on the articular surface.Minor scratches were present around the sides of the insert and some damage was observed on the inferior surface.The baseplate showed apparent scratches on the proximal surface.Scratches appeared to be non-random and were generally oriented in the medial/lateral direction.An edax analysis was run on the sem to determine the elemental composition of these scratches.Several locations were tested and results were consistent showing peaks corresponding to the baseplate¿s materials: titanium, vanadium, and aluminum.The scratches on the baseplate do not correlate with those seen on the inferior surface of the insert which indicates it is likely the baseplate was scratched when the insert was not on the tray.An incomplete cement adhesion was observed on the baseplate surface.A clinical analysis noted no relevant supporting information has been provided to assist with this investigation, and the patient's current condition is unknown.Therefore based on insufficient information, a thorough clinical assessment cannot be performed at this time.Without the return of the actual product involved, our investigation of this report is inconclusive.No further investigation is warranted for this complaint; however we will continue to monitor for future complaints and investigate as necessary.Should additional information be received, the complaint will be reopened.
|
| |
|