Model Number M635TU10060
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Pericardial Effusion (3271)
Date of Event 05/17/2018
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Device evaluated by mfr: it is indicated that the device will not be returned for evaluation.If there is any further relevant information obtained, a supplemental medwatch will be filed.(b)(4).
 
Event or Problem Description
Same case as mdr id: 2134265-2018-05152.It was reported that a pericardial effusion occurred.A left atrial appendage (laa) closure procedure was being performed.A watchman® access system (was) was positioned at the deepest part of the laa that could be safely reached and a 21mm watchman ® laa closure device & delivery system (wds) was advanced.The closure device was deployed in the laa and shortly after deployment, the echocardiographer noticed a growing pericardial effusion.A pericardiocentesis was performed to extract fluid from the pericardium.The patient was stabilized and the closure device was implanted and released from the core wire.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
WATCHMAN® ACCESS SYSTEM
Common Device Name
SYSTEM, APPENDAGE CLOSURE, LEFT ATRIAL
Manufacturer (Section D)
BOSTON SCIENTIFIC - GALWAY
MDR Report Key7577233
Report Number2134265-2018-05153
Device Sequence Number2629738
Product Code NGV
UDI-Device Identifier08714729838197
UDI-Public08714729838197
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
P130013
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 05/17/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date10/31/2020
Device Model NumberM635TU10060
Device Catalogue NumberTU1006
Device Lot Number0021325772
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/17/2018
Initial Report FDA Received Date06/07/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
-
-