MAUDE Adverse Event Report: SIEMENS HEALTHCARE DIAGNOSTICS, INC. ADVIA CENTAUR CP TNI-ULTRA ASSAY; TROPONIN IMMUNOASSAY

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SIEMENS HEALTHCARE DIAGNOSTICS, INC. ADVIA CENTAUR CP TNI-ULTRA ASSAY; TROPONIN IMMUNOASSAY Back to Search Results
Model Number N/A
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 05/18/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The patient sample was drawn into a bd serum separator primary tube, stat spun for 3 minutes and poured off into a secondary transfer tube.The reagents are homogenous.No related errors on the event log.Maintenance is up to date.No other tests with issues.No known shipping or storage issues.Other than the stat spin, all operators handle and store materials according to manufacturer's recommendations.The siemens field service engineer (fse) was sent to the customer site for system inspection.The fse performed a total service call.The fse replaced the acid rotary pump, the luminometer, acid rotary pump, wash 1 rotary pump, gray peri-pump, aspirate probe tubings, and the pcb usb converter.The reagent and sample probe have been calibrated.Uni-load and firmware upgrade were completed.The fse performed a system decontamination and ring cuvette calibration adjustments.The customer has calibrated and ran quality control (qc) on all other assays on the system.Qc is good.Tni-ultra patient pool precision run was good.The cause for the discordant tni-ultra result is unknown.Multiple parts were replaced and probe alignments were performed.The cause could not be determined.The instrument is performing within specifications.No further evaluation of the device is required.The instruction for use (ifu) under the summary and explanation of the test section states the following: "always analyze ctni results in the context of time elapsed since patient presentation to the hospital.Serial sampling is recommended to detect the temporal rise and fall of troponin levels characteristic of mi.In accord with published recommendations, serial testing of ctni at intervals of 2 to 4 hours for up to 12 to 24 hours is suggested to corroborate a single ctni result.An elevated troponin alone is not sufficient to make the diagnosis of mi.Other markers, such as ck-mb and myoglobin, can be used in conjunction with ctni results in aiding the diagnosis of mi." mdr 1219913-2018-00165 was filed for the same event.
 
Event or Problem Description
A false high advia centaur cp troponin ultra (tni-ultra) result was obtained for a patient sample.The result was not reported to the physician.The patient sample was repeated on the same instrument and the other advia centaur cp.The results were lower.The lower results were reported to the physician.Patient treatment was not prescribed or altered.There was no report of adverse health consequences due to the discordant tni-ultra result.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ADVIA CENTAUR CP TNI-ULTRA ASSAY
Common Device Name
TROPONIN IMMUNOASSAY
Manufacturer (Section D)
SIEMENS HEALTHCARE DIAGNOSTICS, INC.
511 benedict avenue
tarrytown NY 10591 5097
MDR Report Key7577840
Report Number1219913-2018-00166
Device Sequence Number19213457
Product Code MMI
UDI-Device Identifier00630414516226
UDI-Public00630414516226
Combination Product (Y/N)N
Initial Reporter StateMI
Initial Reporter CountryUS
PMA/510(K) Number
K053020
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source health professional,user faci
Initial Reporter Occupation Medical Technologist
Type of Report Initial
Report Date (Section B) 06/07/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date08/20/2018
Device Model NumberN/A
Device Catalogue Number10317709
Device Lot Number69853130
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/22/2018
Initial Report FDA Received Date06/07/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-