US SURGICAL PUERTO RICO THORACOPORT; LAPAROSCOPE, GENERAL & PLASTIC SURGERY Back to Search Results
Model Number 179303
Medical Device Problem Codes Break (1069); Detachment Of Device Component (1104)
Health Effect - Clinical Code Device Embedded In Tissue or Plaque (3165)
Date of Event 05/23/2018
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
According to the reporter: occurred during a laparoscopic thoracoscopy procedure.The port was placed between the ribs.When the scope was removed, the cannula broke and the trocar fell into pieces and some fell into the thorax.In order to resolve the issue, pieces of the trocar were removed.However, one little piece was not found and is still in the patient.The patient outcome is reported as alive, no injury.
 
Additional Manufacturer Narrative
Additional information: (expiration date, lot#), evaluation summary: post market vigilance (pmv) led an evaluation of one device.The visual inspection noted: the cannula was broken.The obturator appeared intact.Records from each manufacturing lot are thoroughly reviewed to ensure that products are released meeting all quality release specifications at the time of manufacture.Replication of the broken cannula may occur when mishandled during clinical application.The root cause of the observed damage was misuse of the product which caused or contributed to the reported condition.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
THORACOPORT
Common Device Name
LAPAROSCOPE, GENERAL & PLASTIC SURGERY
Manufacturer (Section D)
US SURGICAL PUERTO RICO
201 sabanetas industrial park
ponce PR 00716 4401
MDR Report Key7584482
Report Number2647580-2018-02796
Device Sequence Number14085167
Product Code GCJ
UDI-Device Identifier10884521081185
UDI-Public10884521081185
Combination Product (Y/N)N
Initial Reporter CountryBE
PMA/510(K) Number
K992288
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Health Professional
Type of Report Initial,Followup
Report Date (Section B) 03/01/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date10/31/2022
Device Model Number179303
Device Catalogue Number179303
Device Lot NumberP7K0849X
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/02/2019
Initial Date Received by Manufacturer 05/23/2018
Supplement Date Received by Manufacturer02/06/2019
Initial Report FDA Received Date06/08/2018
Supplement Report FDA Received Date03/01/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-