Model Number MODEL 100
Medical Device Problem Codes Device Displays Incorrect Message (2591); Device Operational Issue (2914)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 05/18/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The reported event was confirmed through evaluation and archive data review of the autopulse platform (sn (b)(4)).The root cause is due to a defective load cell.Evaluation of the platform during initial power up, revealed a user advisory (ua) 7 (discrepancy between load 1 and load 2 too large) error message on the user control panel.The archive data was reviewed and contained multiple ua 7 error message on the reported event.A load characterization check was performed and identified a defective load cell.As part of routine service during testing, the device was examined and found a damaged short black cover and is not related to the reported event.After replacement of the load cell and the short black cover, the platform was further functionally tested to full specification and operated as intended with no further issues observed.Historical complaints were reviewed for service information related to the reported complaint and there was no previous history of complaint reported for the autopulse platform with serial number (b)(4).
 
Event or Problem Description
During shift check, the autopulse platform (sn (b)(4)) displayed user advisory (ua) 7 (discrepancy between load 1 and load 2 too large) error message.No patient involvement.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AUTOPULSE® RESUSCITATION MODEL 100
Common Device Name
CARDIAC CHEST COMPRESSOR
Manufacturer (Section D)
ZOLL CIRCULATION
2000 ringwood ave.
san jose CA 95131
MDR Report Key7605455
Report Number3010617000-2018-00652
Device Sequence Number283522
Product Code DRM
UDI-Device Identifier00849111001021
UDI-Public00849111001021
Combination Product (Y/N)N
Initial Reporter CountryUK
PMA/510(K) Number
K112998
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 06/15/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberMODEL 100
Device Catalogue Number8700-0740-01
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer05/21/2018
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/18/2018
Initial Report FDA Received Date06/15/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-