MEDACTA INTERNATIONAL SA GMK-HINGE FIXED TIBIAL INSERT SIZE 4/12MM Back to Search Results
Catalog Number 02.09.0412H
Health Effect - Clinical Code Pain (1994)
Date of Event 05/15/2018
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Batch review performed on 15 june 2018: lot 163652: (b)(4) items manufactured and released on 12 october 2016.Expiration date: 2021-07-14 no anomalies found related to the problem.To date, (b)(4) items of the same lot have been already sold without any similar reported event.Clinical evaluation performed by medical affairs director on 12 june 2018: three (3) months after implantation of a constrained hinged system in a severe genu recurvatum, the patient was complaining of pain and instability due to the disengagement of the insert post extension from the femoral component.The fixation screw was found loose in the joint.The reason of self unscrewing of the screw is not known.
 
Event or Problem Description
Revision surgery performed due to post screw unscrewing 3 months after primary, during the revision surgery also the inlay locking screw was found loose in the joint and broken.The patient was operated at the beginning for severe genu recurvatum and was very good after surgery with return to full function.In (b)(6) 2018, the patient came to hospital due to pain and instability, the x-rays showed a complete dissociation of the femur from the tibia and the post locking screw disengagement.During the revision surgery the poly locking screw was also found broken, macroscopic exam reviled wear of the poly on its anterior portion, the liner was revised.
 
Additional Manufacturer Narrative
Additional information received on 17 and 18 june 2018: the tibia was not replaced.The half part of the insert locking screw has been taking out and lost.The new insert was fixed with its locking screw with torque screw driver.The screw was out, stock in the poly liner.Visual inspection performed by r&d product manager: revision surgery after 3 months from primary surgery for complete dissociation of the femur from the tibia.In the x-rays analysis and during revision surgery the hinge post locking screw was found backed out from the post and the insert screw was found broken.Both of them have been returned for analysis.Hinge post screw:the hinge post secure screw backed out from the hinge post.Its threaded part is damaged and plastically pressed.The screw has been plastically deformed once, backed out from the hinge post, was interposed between the femoral component and the tibia insert and underwent to the body load.Due to this deformation, it is no more possible to fix the screw into the hinge post.Hinge tibia insert: articular surfaces of the insert have been damaged with traces of the threaded part of the post-screw.Also the hole to host the insert secure screw is damaged.Due to this deformation it was possible to retain the insert secure screw even if it was broken.Insert secure screw: the screw of the insert is broken in 2 pieces in correspondence to the threaded part of its shaft.Only one piece has been returned.The other remain into the baseplate and was removed manually.Hinge post: no elements relevant for the event can be noted on the hinge post and on its threaded hole.It is not possible to find an explanation for such an unlikely event.Unscrewing of the hinge post screw could have led to disengagement of the post from the femoral component.Due to this disassembling, unpredictable loads could have acted on the insert causing insert screw breakages and consequent dislocation of the insert from the baseplate.Cause for self-unscrewing of the hinge post screw is not known.A torque limiting screwdriver (6 nm) is supplied and its use is mandatory in order to achieve the proper morse taper axial force.The only cause that we can suppose for this event is insufficient tightening torque, either due to a malfunction of the torque limiting device or to improper use or to improper axial alignment of the screw with the post during tightening.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GMK-HINGE FIXED TIBIAL INSERT SIZE 4/12MM
Common Device Name
FIXED TIBIAL INSERT
Manufacturer (Section D)
MEDACTA INTERNATIONAL SA
strada regina
castel san pietro, switzerland 6874
SZ  6874
MDR Report Key7605649
Report Number3005180920-2018-00427
Device Sequence Number1397006
Product Code KRO
UDI-Device Identifier07630030825194
UDI-Public07630030825194
Combination Product (Y/N)N
Initial Reporter CountryIS
PMA/510(K) Number
K130299
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Device Explanted Year2018
Reporter Type Manufacturer
Report Source distributor
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 07/13/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date07/14/2021
Device Catalogue Number02.09.0412H
Device Lot Number163652
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer06/14/2018
Was the Report Sent to FDA? No
Initial Date Received by Manufacturer 05/17/2018
Supplement Date Received by Manufacturer05/17/2018
Initial Report FDA Received Date06/15/2018
Supplement Report FDA Received Date07/13/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age68 YR
Patient Weight88
-
-