DEPUY ORTHOPAEDICS INC US GLOBAL UNITE HEAD 44X15 ECC; GLOBAL UNITE IMPLANTS : HUMERAL TRIALS Back to Search Results
Catalog Number 110044600
Medical Device Problem Code Insufficient Device Problem Information (3190)
Health Effect - Clinical Codes Pain (1994); Not Applicable (3189)
Date of Event 05/30/2018
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
Revision of shoulder arthroplasty ; dr.(b)(6); (b)(6) hospital (b)(6) 2018.Primary implant date (b)(6) 2017.Patient complained of pain and mild instability, 6 months history.Synovectomy, and change of humeral head carried out.40 x 15mm eccentric head implanted.Both humeral stem and glenoid apg+ components were solidly still fixed, left issue.Multiple specimens taken.Patient outcome post surgery: stable shoulder joint.Female patient initials lt, dob: (b)(6).X-rays uploaded to unity.
 
Additional Manufacturer Narrative
Investigation summary: no device associated with this report was received for examination.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Depuy considers the investigation closed.Should additional information be received, the information will be reviewed and the investigation will be re-opened as necessary.If information is obtained that was not available for the initial medwatch , a follow-up medwatch, will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GLOBAL UNITE HEAD 44X15 ECC
Common Device Name
GLOBAL UNITE IMPLANTS : HUMERAL TRIALS
Manufacturer (Section D)
DEPUY ORTHOPAEDICS INC US
700 orthopaedic drive
warsaw IN 46582 0988
MDR Report Key7629128
Report Number1818910-2018-62919
Device Sequence Number1638212
Product Code HSD
UDI-Device Identifier10603295004547
UDI-Public10603295004547
Combination Product (Y/N)N
Initial Reporter CountryAS
PMA/510(K) Number
K101996
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2017
Device Explanted Year2018
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Health Professional
Type of Report Initial,Followup
Report Date (Section B) 05/30/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue Number110044600
Device Lot NumberC87132
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 05/30/2018
Supplement Date Received by Manufacturer11/21/2018
Initial Report FDA Received Date06/22/2018
Supplement Report FDA Received Date11/22/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age55 YR
-
-