• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: COVIDIEN MFG DC BOULDER BIZACT; ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

COVIDIEN MFG DC BOULDER BIZACT; ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES Back to Search Results
Model Number BZ4212A
Medical Device Problem Code Difficult to Open or Close (2921)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 06/07/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
According to the reporter, during a tonsillectomy procedure, the device was difficult/impossible to open.The jaws kept sticking together in closed position after activation when doing the left tonsil (second side).There was slightly more blood loss on the left side tonsil than the right side.The surgeon was using the device correctly and cleaned the instrument several times.Replaced with a new one and it worked much better.There was no patient injury.
 
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Additional Manufacturer Narrative
Evaluation summary: one device was received for evaluation.This device had been used in the treatment or diagnosis of a patient.A review of the lot number reported indicates that the product was within the assigned expiration date at the time of the reported incident.The returned product met specification as received.Visual inspection found no defects, except for a lot of eschar on the jaw plates.Pmv personal performed functional testing with the returned device.Visual inspection of the device found no defects.The device's jaw gap and electrical resistance were found to be within specification.The device was plugged into a test generator and was successfully recognized.The device was activated on simulated tissue ten times with satisfactory results.No alarms occurred during testing.The jaws opened and closed normally.There was a lot of eschar on jaw plates and the device needs more frequent cleaning.The investigation found the device to function normally and within specifications.The instructions for use (ifu) also states, keep the instrument jaws clean.Build-up of eschar may reduce the seal and/or cutting effectiveness.Do not activate the instrument while cleaning.Wipe jaws surfaces and edges with a wet gauze pad as needed.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BIZACT
Common Device Name
ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES
Manufacturer (Section D)
COVIDIEN MFG DC BOULDER
5920 longbow dr
boulder CO 80301 3299
MDR Report Key7629672
Report Number1717344-2018-00846
Device Sequence Number1899337
Product Code GEI
UDI-Device Identifier10884521723016
UDI-Public10884521723016
Combination Product (Y/N)N
Initial Reporter StateGA
Initial Reporter CountryUS
PMA/510(K) Number
K171066
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Health Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 10/04/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberBZ4212A
Device Catalogue NumberBZ4212A
Device Lot Number71930171X
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer06/25/2018
Initial Date Received by Manufacturer 06/07/2018
Supplement Date Received by Manufacturer07/23/2018
08/08/2018
Initial Report FDA Received Date06/22/2018
Supplement Report FDA Received Date08/07/2018
10/04/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age7 YR
-
-