• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: GUANGZHOU WONDFO BIOTECH CO., LTD. ONE STEP MULTI-DRUG ORAL FLUID TEST CUBE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

GUANGZHOU WONDFO BIOTECH CO., LTD. ONE STEP MULTI-DRUG ORAL FLUID TEST CUBE Back to Search Results
Model Number Tcube-9BUP
Medical Device Problem Codes Fail-Safe Design Failure (1222); Nonstandard Device (1420); Device Slipped (1584)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 05/16/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
We have started to report this adverse event since 5.25.However, due to some possible technical problems, we have not successfully submitted the documents.Therefore, we consulted with fda officials and maintained close communication to solve the problem.Fda officials have suggested that we can address the reasons for not being able to report in a timely manner in this section.
 
Event or Problem Description
On (b)(6) 2018, our us client alere randomly selected our product one step multi-drug oral fluid test cube (lot no.W61080201,w61080202,w60680202) for inspection.Fifteen saliva sponge collectors (accessories of the test cube) were selected and it was found that 5 of the 15 foam tips had fallen off.This product meet the internal specifications, is used for diagnosis and the failure of the accessory may lead to a mdr reportable events.The potential failure of the sponge collector may lead to the following consequences: affecting the use of the product; causing risks of eating because the foam tip may be dislodged in the user's mouth.We have conducted an investigation and the causes of the failure are identified as follows: for structural design: the outer surface of the foam tip is not fixed, and it is only affixed by hot-melt adhesive on the end face, which makes it easy to fall off.For process flow: according to the existing product technology, hot-melt adhesives must be spotted to the plastic parts first, and then the sponges will be assembled.The process cannot be controlled due to manual operations, which may cause the hotmelt adhesives to cure in advance and the adhesion is not good.No key parameters for this process, only relying on the visual inspection and control of employees, and the lack of standards for the amount of glue leads to uneven coating.Quality control: no controlled sop for this process.There is only one internal operation guideline, which cannot ensure the operators perform according to the guidelines.Quality supervision is missing.Corrective or removal actions: ask our client to return the products to wondfo, and the products will be put in the designated area and isolated.The involved batches that the accessory failure may exist in are: w61071201, w61071202, w60680201, w60680202, w60880201, w61080201, w61080202, w60980201, w61080402, w60680401 (estimated completion time: 2018-6-15).Reassess the rationality of the existing production processes and the effectiveness of the existing quality control (estimated completion time: 2018-6-30).Revise the relevant sop and retrain the relevant personnel.Only the personnel who pass the exam can take up posts (estimated completion time: 2018-6-30).Replace the products for the customers (estimated completion time: within one month after the products are returned).To date, there have been no reported instances of death or injury associated with this product failure.
 
Event or Problem Description
On (b)(6) 2018, our us client (b)(4) randomly selected our product one step multi-drug oral fluid test cube (lot no.W61080201,w61080202,w60680202) for inspection.Fifteen saliva sponge collectors (accessories of the test cube) were selected and it was found that 5 of the 15 foam tips had fallen off.This product meet the internal specifications, is used for diagnosis and the failure of the accessory may lead to a mdr reportable events.The potential failure of the sponge collector may lead to the following consequences: (1) affecting the use of the product; (2) causing risks of eating because the foam tip may be dislodged in the user's mouth.We have conducted an investigation and the causes of the failure are identified as follows: (1) for structural design: the outer surface of the foam tip is not fixed, and it is only affixed by hot-melt adhesive on the end face, which makes it easy to fall off.(2) for process flow: a) according to the existing product technology, hot-melt adhesives must be spotted to the plastic parts first, and then the sponges will be assembled.The process cannot be controlled due to manual operations, which may cause the hotmelt adhesives to cure in advance and the adhesion is not good.B) no key parameters for this process, only relying on the visual inspection and control of employees, and the lack of standards for the amount of glue leads to uneven coating.(3) quality control: no controlled sop for this process.There is only one internal operation guideline, which cannot ensure the operators perform according to the guidelines.Quality supervision is missing.Corrective or removal actions: (1) ask our client to return the products to (b)(4), and the products will be put in the designated area and isolated.The involved batches that the accessory failure may exist in are: w61071201, w61071202, w60680201, w60680202, w60880201, w61080201, w61080202, w60980201, w61080402, w60680401 (estimated completion time: (b)(6) 2018).(2) reassess the rationality of the existing production processes and the effectiveness of the existing quality control (estimated completion time: (b)(6) 2018).(3) revise the relevant sop and retrain the relevant personnel.Only the personnel who pass the exam can take up posts (estimated completion time: (b)(6) 2018).(4) replace the products for the customers (estimated completion time: within one month after the products are returned).Completion of corrective or removal actions: (1) the recall statement was issued on may 18th, 2018, asking the end users to return the product to abbott.By october 17, 2019, a total number of (b)(4) have been recalled.(2) on june 12th, 2018, the rationality of the existing production processes and the effectiveness of the existing quality control was evaluated.The whole procedures of saliva sponge collectors were evaluated, and the product quality control was effective.(3) on june 9th, 2018, the position of the saliva collector was changed, and the spot position of the hot-melt adhesive was changed from the sampling rod to the sampling pad.Sop-pm-108 "standard operating procedures for saliver collector" was controlled, and have conducted training for relevant staffs.(4) from august to november 2018, the first round of rework on the recalled products was carried out with a total number of (b)(4) has been returned to the customer.In february 2019, the customer refused to accept the remaining reworked products.Therefore, from april to may 2019, the second round of rework was carried out with a total number of 55,400t, and they were reworked into fuo products and converted into wondfo normal products.Later, the remaining products with a number of (b)(4) will be scrapped.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ONE STEP MULTI-DRUG ORAL FLUID TEST CUBE
Common Device Name
ONE STEP MULTI-DRUG ORAL FLUID TEST CUBE
Manufacturer (Section D)
GUANGZHOU WONDFO BIOTECH CO., LTD.
no.8 lizhishan road
science city, luogang district
guangzhou, guangdong 51066 3
CH  510663
MDR Report Key7640778
Report Number3004635103-2018-52508
Device Sequence Number11201152
Product Code PVH
UDI-Device Identifier00858945006881
UDI-Public00858945006881
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source distributor,other
Initial Reporter Occupation Administrator/Supervisor
Remedial Action Recall,Relabeling
Type of Report Initial,Followup
Report Date (Section B) 05/26/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Other
Device Expiration Date02/25/2020
Device Model NumberTcube-9BUP
Device Catalogue NumberTCUBE-10MO
Device Lot NumberW61080202
Was Device Available for Evaluation? Yes
Was the Report Sent to FDA? No
Initial Date Received by Manufacturer 05/16/2018
Supplement Date Received by Manufacturer05/16/2018
Initial Report FDA Received Date06/27/2018
Supplement Report FDA Received Date05/28/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-