Catalog Number 305924
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 05/15/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Event or Problem Description
It was reported with the use of a bd safetyglide¿ shielding hypodermic the needle was found leaking as "during injection of vaccine, the majority of the vaccine passed the seal of the plunger and backed to the barrel of the syringe.The client did not receive a full dose and they were required to inject the child a second time to administer a complete full dose.Upon closer inspection of the syringe, it was noted that the plunger was misshaped on one side." there was no report of exposure, injury, or medical intervention.
 
Additional Manufacturer Narrative
H.6.Investigation summary: two photos were received showing 3ml syringes reported to be from batch # 7093907 (p/n # 305924).The photos were evaluated.The photos show one loose syringe with an insecure stopper ¿ the stopper was not fully attached to the plunger rod tip.The insecure stopper observed is rejectable per product specification.Furthermore, a device history record review showed no rejected inspections or quality issues during the production of the provided lot number that could have contributed to the reported defect.In addition, the potential root cause for the insecure stopper defect is associated with the assembly process.No corrective actions are necessary based on the defective rate identified.Investigation conclusion: potential root cause for the insecure stopper defect is associated with the assembly process.
 
Event or Problem Description
It was reported with the use of a bd safetyglide¿ shielding hypodermic the needle was found leaking as "during injection of vaccine, the majority of the vaccine passed the seal of the plunger and backed to the barrel of the syringe.The client did not receive a full dose and they were required to inject the child a second time to administer a complete full dose.Upon closer inspection of the syringe, it was noted that the plunger was misshaped on one side." there was no report of exposure, injury, or medical intervention.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD SAFETYGLIDE¿ SHIELDING HYPODERMIC NEEDLE
Common Device Name
HYPODERMIC SINGLE LUMEN NEEDLE
Manufacturer (Section D)
BECTON DICKINSON MEDICAL SYSTEMS
route 7 and grace way
canaan CT 06018
MDR Report Key7648761
Report Number1213809-2018-00382
Device Sequence Number168962
Product Code FMI
UDI-Device Identifier30382903059240
UDI-Public30382903059240
Combination Product (Y/N)N
Initial Reporter CountryCA
PMA/510(K) Number
K951254
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source foreign,other,user facility
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 07/13/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Other
Device Expiration Date03/31/2022
Device Catalogue Number305924
Device Lot Number7093907
Initial Date Received by Manufacturer 06/07/2018
Supplement Date Received by Manufacturer06/07/2018
Initial Report FDA Received Date06/28/2018
Supplement Report FDA Received Date07/19/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-