| Model Number |
M004218500 |
| Medical Device Problem Code |
Device Remains Activated (1525)
|
| Health Effect - Clinical Code |
No Consequences Or Impact To Patient (2199)
|
| Date of Event |
06/06/2018
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Device evaluated by mfr: the device has not been received for analysis.Upon receipt and completion of the failure analysis of the complaint device, if there is any further relevant information from that review, a supplemental medwatch will be filed.(b)(4).
|
| |
|
Event or Problem Description
|
|
It was reported that the device was unable to halt ablation.A maestro foot switch was used in a trioventricular reentrant tachycardia ablation.However during ablation the physician tried end the ablation using maestro foot switch but ablation did not stop.Ablation was then stopped manually which led to 4sec longer ablation then planned.The procedure was completed with this device.No patient complications were reported.
|
| |
|
Event or Problem Description
|
|
It was reported that the device was unable to halt ablation.A maestro foot switch was used in a trioventricular reentrant tachycardia ablation.However during ablation the physician tried end the ablation using maestro foot switch but ablation did not stop.Ablation was then stopped manually which led to 4sec longer ablation then planned.The procedure was completed with this device.No patient complications were reported.
|
| |
|
Additional Manufacturer Narrative
|
|
Updated: device avail.For eval., returned to mfr.On., device returned to mfr., device evaluated by mfr., eval summary, method codes, results codes, conclusion codes.Device evaluated by manufacturer - the foot guard was in overall good physical condition.The strain relief guard over cord was in good physical shape.No damage was noted to the cord¿s insulation jacket.The pedal presses down evenly with normal clicking sound.The connector to maestro is in good physical shape.Pins are straight and grounding shield is intact.Using an ohm meter the foot switch was placed on the floor and activated.The switch turned on off with no issues.The cord was pulled and flexed along the length and near the connector and pedal¿s strain reliefs.No issues observed.The foot switch passed all electrical and functional testing.When removing the foot pedal¿s cover, the trigger mechanism could move out of place.However, when the cover was put back on, the trigger mechanism moved back to the correct orientation.A service history review was performed on the rf ablation foot switch.There was found nothing to indicate any possible service-related causes for the complaint.The investigation conclusion is design specification as the device problem was traced back to the design specifications.(b)(4).
|
| |
|