MAUDE Adverse Event Report: COOK BIOTECH BIODESIGN HERNIA GRAFT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

COOK BIOTECH BIODESIGN HERNIA GRAFT Back to Search Results
Model Number G36033
Medical Device Problem Code Insufficient Device Problem Information (3190)
Health Effect - Clinical Codes Adhesion(s) (1695); Pain (1994)
Date of Event 06/20/2018
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Date of event not provided by the complainant.Lot number not provided by the complainant.Implant date not provided by the complainant.A review of the device lot history records indicated that the device was manufactured to specifications.A total of two devices was produced from the lot.A review of the cbi complaint database revealed no additional complaints involving the reported lot number.Adhesion is noted amongst the list of potential complications provided in the ifu.The root cause, of the reported device adhesion to the small bowel, is inconclusive at this time.A specimen was returned to cbi and will be sent for histopathology testing.A follow-up mdr and root cause summary will be documented once results of the histopathology testing are received.
 
Event or Problem Description
In (b)(6) 2015, dr.(b)(6) placed a biodesign hernia graft for repair of an incisional hernia.In 2018, the patient was seen for complaints of pain.Dr.(b)(6) reoperated and found the device adhered to the small bowel, not incorporated, and crumpled.The device was reportedly explanted.
 
Event or Problem Description
In (b)(6) 2015, dr.(b)(6) placed a biodesign hernia graft for repair of an incisional hernia.In 2018, the patient was seen for complaints of pain.Dr.(b)(6) reoperated and found the device adhered to the small bowel, not incorporated, and crumpled.The device was reportedly explanted.Update #1: an explanted specimen was received at cbi on 07/03/2018.The specimen underwent histopathology testing by cook research incorporated's veterinary pathologist.The testing revealed that partially remodeled sis was identified amongst the fibrofatty tissue and aggregates.The sis was mostly surrounded by mature fibrous connective tissue.The sis contained a few fibrous connective tissue bands.Inflammation was minimal and composed of few lymphocytes and plasma cells and rare granulocytes usually in the connective tissue surrounding the sis.Surrounding the sis, dense mature connective tissue contained stiff black suture-like material.No sutures were identified within the sis.Update #2: additional details were received.Per the patient's medical records, the following details were obtained.On (b)(6) 2015: a ct scan revealed a large hernia defect in the infraumbilical anterior abdominal wall.The defect had a transverse dimension of approximately 7.8 cm and a craniocaudal extent of approximately 11.5 cm.There was herniation of mesentery, omentum, small bowel and a portion of the large bowel into the defect.The content of the hernia sac extended predominantly to the right of midline.A linear density was noted anterior to the hernia, which may have represented previous mesh, however correlation with clinical features was suggested.Additionally, a well defined cyst measuring 2.9 x 2.7 cm was noted on the right ovary.On (b)(6) 2015: on (b)(6) 2015, the patient underwent an incisional hernia repair with component separation.The reason for surgery was a recurrent incisional hernia.A 10x7 cm defect was present in the infraumbilical region.Biodesign was placed intraperitoneally.A prolene mesh was placed above the rectus sheath.Two drains were placed, flaps were raised, and the incision was closed in layers.The patient was discharged on (b)(6) 2015.On (b)(6) 2018: a ct scan was performed and the impression was an essentially normal study of the whole abdomen.The small and large bowel loops were normal in caliber and distribution.The colon was loaded with air mixed residue.There was no definite stricture formation or bowel obstruction noted.On (b)(6) 2018: the patient presented with complaints of vomiting and abdominal pain for one month and abdominal distention with constipation.The vomiting occurred immediately after meals.The abdominal pain was in the mid epigastric to chest region.On(b)(6) 2018, the patient underwent a laparoscopic adhesiolysis.Findings from the procedure included adhesions around the umbilicus and multiple ileo-ileal intussusception.The adhesions were taken down and the intussusception was relieved.A specimen was sent for pathology.The patient was transferred to (b)(6) hospital and discharged on (b)(6) 2018.
 
Additional Manufacturer Narrative
A review of the device lot history records indicated that the device was manufactured to specifications.A total of two devices was produced from the lot.A review of the cbi complaint database revealed no additional complaints involving the reported lot number.Adhesion is noted amongst the list of potential complications provided in the ifu.The root cause, of the reported device adhesion to the small bowel, is inconclusive at this time.A specimen was returned to cbi and will be sent for histopathology testing.A follow-up mdr and root cause summary will be documented once results of the histopathology testing are received.Update #1: adhesions and portions of sis were identifiable in the examined specimen.Adhesions are a known potential complication of most abdominal procedures.The root cause of the adhesions is inconclusive.However, many factors can influence and contribute to adhesion formation including, but not limited to, a patient's tendency to form adhesions, an abdominal procedure, any damage to the bowel during the initial surgery, excessive tissue incisions, history of prior surgeries, excessive handling of viscera, post-operative activities, nutrition, and the overall state of health of the patient.It is possible that the foreign suture material found in the specimen contributed to the adhesions and lack of complete device incorporation.However, this cannot be confirmed nor ruled out.Lastly, the sis may not have fully remodeled due to the adhesion formations.This also cannot be confirmed nor ruled out.Update #2: the summary in update #1 remains pertinent.Medical records indicated the patient had a history of abdominal surgeries and adhesions.
 
Additional Manufacturer Narrative
A review of the device lot history records indicated that the device was manufactured to specifications.A total of two devices was produced from the lot.A review of the cbi complaint database revealed no additional complaints involving the reported lot number.Adhesion is noted amongst the list of potential complications provided in the ifu.The root cause, of the reported device adhesion to the small bowel, is inconclusive at this time.A specimen was returned to cbi and will be sent for histopathology testing.A follow-up mdr and root cause summary will be documented once results of the histopathology testing are received.Update: adhesions and portions of sis were identifiable in the examined specimen.Adhesions are a known potential complication of most abdominal procedures.The root cause of the adhesions is inconclusive.However, many factors can influence and contribute to adhesion formation including, but not limited to a patient's tendency to form adhesions, an abdominal procedure, any damage to the bowel during the initial surgery, excessive tissue incisions, history of prior surgeries, excessive handling of viscera, post-operative activities, nutrition, and the overall state of health of the patient.It is possible that the foreign suture material found in the specimen contributed to the adhesions and lack of complete device incorporation.However, this cannot be confirmed nor ruled out.Lastly, the sis may not have fully remodeled due to the adhesion formations.This also cannot be confirmed nor ruled out.
 
Event or Problem Description
In (b)(6) 2015, dr.(b)(6) placed a biodesign hernia graft for repair of an incisional hernia.In 2018, the patient was seen for complaints of pain.Dr.(b)(6) reoperated and found the device adhered to the small bowel, not incorporated, and crumpled.The device was reportedly explanted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BIODESIGN HERNIA GRAFT
Common Device Name
HERNIA GRAFT
Manufacturer (Section D)
COOK BIOTECH
1425 innovation place
west lafayette IN 47906
MDR Report Key7664320
Report Number1835959-2018-00009
Device Sequence Number11144129
Product Code OXK
UDI-Device Identifier10827002360331
UDI-Public(01)10827002360331(17)160331(10)LB763019
Combination Product (Y/N)N
Initial Reporter CountryIN
PMA/510(K) Number
K133306
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2015
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date (Section B) 09/05/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date03/31/2016
Device Model NumberG36033
Device Catalogue NumberC-SLH-8H-20X20
Device Lot NumberLB763019
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/03/2018
Initial Date Received by Manufacturer 06/20/2018
Supplement Date Received by Manufacturer07/24/2018
09/03/2018
Initial Report FDA Received Date07/05/2018
Supplement Report FDA Received Date07/30/2018
09/19/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
NONE WERE REPORTED BY THE COMPLAINANT.; NONE WERE REPORTED BY THE COMPLAINANT.; PROLENE MESH ON (B)(6) 2015; NONE WERE REPORTED BY THE COMPLAINANT.
Outcome Attributed to Adverse Event Required Intervention;
Patient Age39 YR
-
-