MMJ SA DE CV (USD) SHILEY; TUBE TRACHEOSTOMY AND TUBE CUFF Back to Search Results
Model Number 4.0PED
Medical Device Problem Code Material Discolored (1170)
Health Effect - Clinical Code No Patient Involvement (2645)
Date of Event 06/21/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
According to the reporter, prior to use, tubing was discolored.There was no patient involvement.
 
Additional Manufacturer Narrative
Evaluation summary: the incident sample was returned for evaluation and a visual inspection revealed there was some discoloration of the tube.A review of manufacturing process revealed that the container used to wash the tubing , using lysol and water, was too small and the liquids were not fully mixed together which probably caused the discoloration.The work instruction for this step of the manufacturing process was updated with pictures and comments to ensure the proper size of container will be used for this step of the process.If information is provided in the future, a supplemental report will be issued.
 
Additional Manufacturer Narrative
This event has been reassessed and found to be a non-mdr reportable complaint.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SHILEY
Common Device Name
TUBE TRACHEOSTOMY AND TUBE CUFF
Manufacturer (Section D)
MMJ SA DE CV (USD)
ave henequen no 1181 desarroll
ciudad juarez,ci 32590
MX  32590
MDR Report Key7666733
Report Number2936999-2018-00432
Device Sequence Number11420453
Product Code JOH
UDI-Device Identifier30884522026714
UDI-Public30884522026714
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K945513
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source distributor,foreign,user faci
Initial Reporter Occupation Other
Type of Report Initial,Followup,Followup
Report Date (Section B) 10/19/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date05/09/2022
Device Model Number4.0PED
Device Catalogue Number4.0PED
Device Lot Number17E0250JZX
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer08/15/2018
Initial Date Received by Manufacturer 06/21/2018
Supplement Date Received by Manufacturer09/05/2018
09/05/2018
Initial Report FDA Received Date07/06/2018
Supplement Report FDA Received Date10/04/2018
10/19/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-