Kaveh barami, indro chakrabarti, james silverthorn, jeremy ciporen, paul t.Akins.Diagnosis, classification, and management of fourth ventriculomegaly in adults: report of 9 cases and literature review.World neurosurgery (2018).Doi: 10.1016/j.Wneu.2018.05.073 - objective: an enlarged fourth ventricle, otherwise known as fourth ventriculomegaly (4th vm), has been reported previously in the pediatric population, yet literature on adults is scant.We report our experience with 4th vm in adults over an 11-year period and review the literature.- materials and methods: this was a retrospective chart review of adult patients with the diagnosis of 4th vm admitted to the intensive care unit in a tertiary care center.- results: nine patients were identified with 4th vm.Most presented with symptoms in the posterior fossa.Five cases were related to previous shunting and the underlying neurosurgical diseases, and average time interval to develop symptoms was 5.3 years.We divided our cases into primary, acquired, and degenerative based on the pathophysiology involved.Treatments included extended subzero cerebrospinal fluid diversion using a frontal external ventricular drain followed by low-pressure shunt revision, endoscopic third ventriculostomy, suboccipital decompression, and fourth ventricular ca theter placement.Literature review identified additional published cases, and there were no reports of a formal classification scheme or treatment algorithm.- conclusions: this case series illustrates a narrow spectrum of etiologies associated with 4th vm in adults.We propose a simple classification scheme dividing 4th vm into 3 categories: primary, acquired, and degenerative.We recommend a stepwise treatment approach starting with extended subzero cerebrospinal fluid diversion followed by shunting for symptomatic primary and acquired 4th vm.Lower success rates and greater morbidity are associated with rescue procedures such as fourth ventricle drainage catheters, endoscopic third ventriculostomies, and skull base decompression.Reported events.At (b)(6), a female patient with a complicated childhood neurosurgery history transitioned from her pediatric neurosurgeon to an adult neurosurgeon with worsening upper extremity function and an enlarging cervical syrinx.At the (b)(6), she presented with headaches, emesis, bilateral sixth nerve palsies, and communicating hydrocephalus of unknown cause.A ventriculoperitoneal shunt (vps) was placed.Two years after initial presentation, repeat neuroimaging identified small foci of subarachnoid enhancement in the posterior fossa, basal cisterns, an encapsulated lumbosacral lesion, and an enhancing thoracic tumor.She underwent subtotal resection of the lumbar tumor.The pathology was a juvenile pilocytic astrocytoma.With chemotherapy, the posterior fossa lesions decreased in size, but the midthoracic tumor enlarged.At (b)(6), she underwent subtotal resection of the thoracic tumor followed by spinal radiation and concurrent temozolomide.The tumor progressed, and she underwent a second thoracic spinal cord operation and further radiosurgery and chemotherapy.Serial neuroimaging over an 11-year follow-up period has not identified any recurrence of tumor.During her treatments, she developed symptomatic multiloculated cervical and thoracic syringomyelia leading to a syringopleural shunt and a chiari decompression at (b)(6).She had multiple revisions of her cerebrospinal fluid (csf) shunts and stabilized for several years with a right occipital vps with a programmable strata valve (medtronic, (b)(4)) attached by a t connector to a fourth ventricle catheter and a peritoneal catheter.
|