Patient information not available for reporting.Device malfunctioned intra-operatively and was not implanted / explanted.Initial reporter is synthes sales consultant.A review of the device history records has been requested.Subject device has been received and is currently in the evaluation process.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Additional narrative: date of manufacture device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Additional narrative: device history records review was completed for part# 07.704.005s, lot# dse6761.Manufacturer: dsm biomedical - kensey nash, release to warehouse date: nov 30, 2017, expiry date: jul 28, 2019.No non-conformance reports were generated during production.Review of the device history records showed that there were no issues during the manufacture of the product that would contribute to this complaint condition.Product investigation was completed.The norian drillable was received with cement present in the rotary pouch.There is some cement present in the delivery syringe and the remainder of the cement is in the pouch at the interface with the syringe.The complaint was not able to be replicated because a functional test could not be completed as the cement has already hardened with in the rotary pouch.This is consistent with the reported complaint condition, thus confirming the complaint.Dimensional analysis is not applicable due to the returned condition of the product, hardened cement within the pouch.Relevant drawings were reviewed.There is no indication that a design or manufacturing issue contributed to the complaint.While no definitive root cause could be determined it is likely that the cement was not implanted within the 5-minute maximum time frame refenced in the relevant technique guide, norian drillable inject surgical technique.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|