BAUSCH + LOMB 23 GA POSTERIOR PROCEDURAL PACK WITH INTEGRATED VENTED AFI & WF; UNIT, PHACOFRAGMENTATION Back to Search Results
Model Number BL5523WV
Medical Device Problem Code Failure to Cut (2587)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 06/18/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Manufacturing and sterilization records were reviewed and found to be acceptable.
 
Event or Problem Description
The user facility in (b)(6) reported that the surgeon noticed that the cutter failed to be cutting though still aspirating during core vitreous removal.Cutter was removed from the eye and tested in gallipot at 1000cpm and again at 5000cpm to no effect.As a result, a new pack was opened and cutter was replaced.The surgery was completed successfully with no effect on the patient.
 
Additional Manufacturer Narrative
The product evaluation has been completed.One 23ga vit cutter was returned in the remote control drape.The remote control drape was stapled to the bl5523wv pack label from lot v8909.The expiration date on the label was 2018-08-14.The tip protector was in place.However, the needle was bent.The port window was in the opened position.There was dried solution in the tubing.The back cap was aligned correctly with the vent hole in the side of the cutter body.The connectors were inspected and no damage was found.A functional test was performed using a stellaris pc system.The cutter does not cut.The inner needle does not reach the cutting edge, it stops at about the center of the port.The cutter continues to aspirate, but cannot cut.It should be noted that a bent needle could contribute to poor cutting performance due to the friction that is caused between the inner and the outer needle at the bent area.The cause of the bent needle cannot be determined.The plant evaluation has been finalized.A review of the complaint database revealed no other complaints for reason code: cutting problem have been submitted against lot v8909.The trend review performed indicates that the product is within control limits.Capa 610815 was closed on 06 july 2018 but was still open when lot v8909 was manufactured (14 march 2017).The root cause investigation concluded that the most likely root cause for the increase in cutter problems is attributable to 1) internal cutter friction 2) tube set design 3) cutter test method.Per capa 610815 and (b)(4) the vitrectomy tubeset used on the stellaris pc packs and standalone pouched vitrectomy cutters was replaced with a new vitrectomy tubeset.The new vitrectomy tubeset provides a greater operating range between the pressure required to close the vitrectomy cutter inner needle and the pressure required to open the vitrectomy cutter inner needle.The vitrectomy tubeset enhancement was implemented on the impacted pc packs and pouched accessories in june 2018.The complaint lot v8909 was manufactured in march of 2017 prior to this change.The first lot of bl5523wv product built in june 2018 with the vitrectomy tubeset enhancement was lot number w1840.Any product with lot number w1840 or higher will include the vitrectomy tubeset enhancement.No further investigation is necessary.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
23 GA POSTERIOR PROCEDURAL PACK WITH INTEGRATED VENTED AFI & WF
Common Device Name
UNIT, PHACOFRAGMENTATION
Manufacturer (Section D)
BAUSCH + LOMB
rochester NY 14609
MDR Report Key7679143
Report Number0001920664-2018-00072
Device Sequence Number16486336
Product Code HQC
UDI-Device Identifier00757770058549
UDI-Public(01)00757770058549(17)180814
Combination Product (Y/N)Y
Initial Reporter CountrySN
PMA/510(K) Number
K101325
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source foreign,health professional,u
Initial Reporter Occupation Health Professional
Type of Report Initial,Followup
Report Date (Section B) 06/18/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date08/14/2018
Device Model NumberBL5523WV
Device Catalogue NumberBL5523WV
Device Lot NumberV8909
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer Not provided
Supplement Date Received by ManufacturerNot provided
Initial Report FDA Received Date07/11/2018
Supplement Report FDA Received Date08/01/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-