| Model Number |
N/A |
| Medical Device Problem Code |
Break (1069)
|
| Health Effect - Clinical Code |
Device Embedded In Tissue or Plaque (3165)
|
| Date of Event |
02/12/2018
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Exemption number e2016018 b.Braun medical, inc.(importer) is submitting this report on behalf of b.Braun melsungen ag (manufacturer).This report has been identified as b.Braun melsungen ag internal report # (b)(4).Device history record review (dhr): reviewed the device history record and no abnormalities found during in process and final control inspection.Sample evaluation: received one introcan safety pur 20g, 1.1x32mm-ap catheter hub without original packaging, with its hub attached to an extension set.The cannula and the protective cap were not returned.By visually checking the received sample, the capillary of the sample was found damaged and the broken part of the capillary was found in a container upon receipt.Complaint and sample to be forwarded to production for further investigation.
|
| |
|
Event or Problem Description
|
|
As reported by the user facility (translation of user facility information by bbm sales organization in hong kong: catheter in artery line was broken.
|
| |
|
Additional Manufacturer Narrative
|
|
Exemption number e2016018.B.Braun medical, inc.(importer) is submitting this report on behalf of b.Braun melsungen ag (manufacturer).This report has been identified as b.Braun melsungen ag internal report # (b)(4).Cut off capillary defect most likely not appear to be attributed by manufacturing process as the defect is able to be detected by the in-line vision system.Damages induced after assembly process is not possible since the catheter had been protected with the protective cap.The simulation by cannula reinsertion did not produce similar defect as per complaint sample.The complaint sample defect matches with the simulation sample of being cut by scissors.The defect on the complaint sample is believed to be occurred after the cannulation process due to been cut by a sharp tool.Cause : defect due to wrong handling.
|
| |
|
Additional Manufacturer Narrative
|
|
Exemption number e2016018.(b)(4) (importer) is submitting the report on behalf of b.Braun melsungen ag (manufacturer).This report has been identified as b.Braun medical inc.Internal report number (b)(4).This follow up report is being filed to correct the branding, product code, and 510(k) information that was entered on the initial mdr.This report was filed for item number, 4251644-03, which is not sold in the united states, however a similar item number, 4251644-02, is sold in the united states by (b)(4).The 510(k) has been updated to reflect a 510(k) that item 4251644-02 has been cleared under.Note: b.Braun is aware that the listed exemption has been withdrawn, however since the initial mdr report was filed under this exemption, the follow up is also being filed under the exemption.
|
| |
|