• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: SIEMENS HEALTHCARE DIAGNOSTICS, INC. ADVIA CENTAUR XP ENHANCED ESTRADIOL (EE2); ENHANCED ESTRADIOL IMMUNOASSAY

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SIEMENS HEALTHCARE DIAGNOSTICS, INC. ADVIA CENTAUR XP ENHANCED ESTRADIOL (EE2); ENHANCED ESTRADIOL IMMUNOASSAY Back to Search Results
Model Number N/A
Medical Device Problem Code No Apparent Adverse Event (3189)
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 06/12/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The cause for the discordant enhanced estradiol (ee2) results is unknown.Siemens healthcare diagnostics is investigating.The enhanced estradiol ifu states in the interpretation of results section: "results of this assay should always be interpreted in conjunction with patient's medical history, clinical presentation and other findings." mdr 1219913-2018-00185 and 1219913-2018-00189 were filed for the same event.
 
Event or Problem Description
A false high advia centaur xp enhanced estradiol (ee2) result was obtained on a patient sample.The result was reported to the patient.The patient provided a previous lower result from an alternate method.The laboratory requested a new collection.The new sample was tested on the advia centaur xp ee2 assay and the result was high.The sample was then sent to the laboratory of support and electrochemiluminescence testing was performed.The result was lower.The patient sample was tested after recentrifugation, neat and diluted, during technical visits, the results were high.The patient is in the postmenopausal phase and does not take hormonal supplementation.Patient treatment was not prescribed or altered.There was no report of adverse health consequences as a result of these discordant enhanced estradiol results.
 
Additional Manufacturer Narrative
Siemens filed the initial mdr on july 16, 2018.08/08/2018 additional information: advia centaur xp enhanced estradiol (ee2) discordant patient results versus alternate method.Female postmenopausal patient results higher than expected when tested for estradiol on the advia centaur xp.Quality control and other patient samples are not affected.This issue only affected this patient sample.Sample is not available for further internal investigation.Previous draws from this patient gave similar results on the advia centaur xp enhanced estradiol (ee2) assay.A list of medications taken by this patient was provided but none have been tested or have claims listed under the limitations section of the instructions for use.While the exact root cause of falsely elevated result cannot be determined, a non-specific interferent cannot be ruled out.Immunoassays are subject to a number of interferences including those caused by endogenous antibodies.Interference can occur because of heterophile antibodies, anti-animal antibodies and auto antibodies.Patients exposed to animals or animal serum products can be prone to this interference and anomalous values may be observed.The interfering antibodies can give rise to a falsely high or less commonly a falsely low result.The erroneous result is recognized as being inconsistent with the patient's clinical picture.Please note the interferent may not necessarily be due to an interfering antibody but may be due to other exogenous interferences such as drugs, nutritional supplements and/or herbal medicine in the blood.A product non-conformance has not been confirmed during this investigation.The instrument is performing within specifications.No further evaluation of the device is required.The ifu states in the limitations section: "heterophilic antibodies in human serum can react with reagent immunoglobulins, interfering with in vitro immunoassays.Patients routinely exposed to animals or to animal serum products can be prone to this interference and anomalous values may be observed.Additional information may be required for diagnosis." mdr 1219913-2018-00185 supplemental report 1 and 1219913-2018-00189 supplemental report 1 were filed for the same event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ADVIA CENTAUR XP ENHANCED ESTRADIOL (EE2)
Common Device Name
ENHANCED ESTRADIOL IMMUNOASSAY
Manufacturer (Section D)
SIEMENS HEALTHCARE DIAGNOSTICS, INC.
511 benedict avenue
tarrytown NY 10591 5097
MDR Report Key7691841
Report Number1219913-2018-00188
Device Sequence Number2770952
Product Code CHP
UDI-Device Identifier00630414574646
UDI-Public00630414574646
Combination Product (Y/N)N
Initial Reporter CountryBR
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 08/09/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date08/02/2018
Device Model NumberN/A
Device Catalogue Number10491445
Device Lot Number58505042
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 06/27/2018
Supplement Date Received by Manufacturer08/08/2018
Initial Report FDA Received Date07/16/2018
Supplement Report FDA Received Date08/09/2018
Patient Sequence Number1
Patient Age58 YR
-
-