MAUDE Adverse Event Report: TRIMEDYNE, INC. 20373-HP OMNITIP SIDEFIRE STIP W/ SUCTION/IRRIGATN; LASER FIBER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

TRIMEDYNE, INC. 20373-HP OMNITIP SIDEFIRE STIP W/ SUCTION/IRRIGATN; LASER FIBER Back to Search Results
Model Number 20373-HP
Medical Device Problem Codes Material Discolored (1170); Melted (1385); Overheating of Device (1437); Material Separation (1562); Use of Device Problem (1670); Material Twisted/Bent (2981)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 05/30/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).Note: this event was initially determined to not be reportable based on the initial report.However, additional information provided by the customer on 06/15/2018 led to the decision to report.Other firm reference number: (b)(4).
 
Event or Problem Description
Customer stated that the 20471-hp was fused and shrunk in the middle of the handpiece when it was used together with 20371-hp.It only had a little energy output after lasing less than 1 minute.Our qc found it is still passing light.Customer stated at a later date "after the fiber assembly was connected to the equipment, the doctor stepped on the pedals for less than 1 minute.He stopped using the camera when the handle had been melted and the doctor's hand was burnt.There are no problems with checking the handles and equipment." this information is documented as reported to trimedyne, inc.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
20373-HP OMNITIP SIDEFIRE STIP W/ SUCTION/IRRIGATN
Common Device Name
LASER FIBER
Manufacturer (Section D)
TRIMEDYNE, INC.
5 holland, building 223
irvine CA 92618 2579
MDR Report Key7705173
Report Number1419951-2018-00003
Device Sequence Number16332865
Product Code GEX
UDI-Device IdentifierM47320373HP0
UDI-PublicM47320373HP0
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K022655
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source distributor,user facility
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 07/19/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Other
Device Expiration Date07/31/2021
Device Model Number20373-HP
Device Catalogue Number20373-HP
Device Lot Number17J026
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/09/2018
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 06/04/2018
Initial Report FDA Received Date07/19/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age60 YR
Patient Weight55
-
-