Catalog Number 400SMTXSFT0101
Medical Device Problem Code Difficult or Delayed Separation (4044)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 06/23/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The product was not returned for evaluation.Without the return of the device, the root cause of the problem cannot be determined.The manufacturing records for this lot were reviewed and did not reveal any outstanding discrepancies, design, or quality concerns.This report is associated with mfr report numbers: 3005168196-2018-01455.
 
Event or Problem Description
The patient was undergoing a coil embolization procedure in the anterior communicating artery (acom) using penumbra smart coils (smart coils) and a penumbra smart coil detachment handle (handle).During the procedure, the physician placed four smart coils in the target vessel using a non-penumbra microcatheter and a handle.The physician then advanced a new smart coil in the target vessel and used the handle to detach it; however, the smart coil failed to detach.Therefore, the physician decided to withdraw it; however, as the physician was pulling the smart coil back, it unintentionally detached inside the microcatheter.The physician then used a wire to successfully push the detached coil into the aneurysm.The procedure was completed using the same microcatheter, the same handle and another smart coil.There was no report of an adverse effect to the patient.
 
Additional Manufacturer Narrative
This report is associated with mfr report number: 3005168196-2018-01455.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PENUMBRA SMART COIL
Common Device Name
HCG, KRD
Manufacturer (Section D)
PENUMBRA, INC.
one penumbra place
alameda CA 94502
MDR Report Key7716133
Report Number3005168196-2018-01454
Device Sequence Number903827
Product Code HCG
UDI-Device Identifier00814548015163
UDI-Public00814548015163
Combination Product (Y/N)Y
Initial Reporter StateNY
Initial Reporter CountryUS
PMA/510(K) Number
K160832
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 06/25/2018
Report Date (Section F) 01/01/2005
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date08/22/2022
Device Catalogue Number400SMTXSFT0101
Device Lot NumberF78795
Was Device Available for Evaluation? No
Was the Report Sent to FDA? Yes
Date Report to Manufacturer01/10/2005
Initial Date Received by Manufacturer 06/25/2018
Supplement Date Received by Manufacturer01/14/2005
Initial Report FDA Received Date07/24/2018
Supplement Report FDA Received Date12/20/2019
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age73 YR