Model Number 4986850
Health Effect - Clinical Code No Known Impact Or Consequence To Patient (2692)
Date of Event 07/03/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Product was not returned to the manufacturer for evaluation.Therefore, we are unable to determine the definitive cause of the reported event.If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
Procedure: oblique lumbar interbody fusion levels implanted: l4/5 it was reported that the patient presented with lcs.Intra-op, when inserting the cage with inserter, the posterior part of the cage was broken and separated.No patient symptoms or complications were reported as a result of this event.About 1/5 of the reported product was broken on the side where it was attached to the inserter.About 4/5 was placed by the judgement of the doctor.The fragment of the cage broken intra-operatively was removed.
 
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Additional Manufacturer Narrative
Product analysis: approximately 15mm of the back side of the cage was returned.There are witness marks on the back side of the cage that appear to be from impaction.The impact marks on the cage are heavy and the fracture surface gives an indication of material overload.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CLYDESDALE PTC SPINAL SYSTEM
Common Device Name
INTERVERTEBRAL FUSION DEVICE WITH BONE GRAFT, LUMBAR
Manufacturer (Section D)
MSD DEGGENDORF MFG
wertstrasse 17
deggendorf 94469
MDR Report Key7737216
Report Number1030489-2018-01085
Device Sequence Number634357
Product Code MAX
UDI-Device Identifier00643169190528
UDI-Public00643169190528
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K133205
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date (Section B) 10/23/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/05/2025
Device Model Number4986850
Device Catalogue Number4986850
Device Lot Number71DC
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/25/2018
Initial Date Received by Manufacturer 07/03/2018
Supplement Date Received by Manufacturer08/08/2018
10/04/2018
Initial Report FDA Received Date07/31/2018
Supplement Report FDA Received Date10/02/2018
10/23/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-