MAUDE Adverse Event Report: BIO-RAD MEDICAL DIAGNOSTICS GMBH TANGO OPTIMO; AUTOMATED BLOOD BANK ANALYSER SYSTEM

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BIO-RAD MEDICAL DIAGNOSTICS GMBH TANGO OPTIMO; AUTOMATED BLOOD BANK ANALYSER SYSTEM Back to Search Results
Model Number 848900010
Health Effect - Clinical Code No Information (3190)
Date of Event 05/31/2018
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
This is our initial report on this incident.
 
Event or Problem Description
The customer reported about false blood group result when testing with erytye s abd rev a1,b on tango optimo.One patient sample that was a true a rh d positive was assigned the test result o rh d negative.The customer received a discrepancy message from lis as historical data from the patient was known.Repeat testing and manual testing confirmed the true type of sample 1.The second sample (sample 2), a true type o rh d positive, was assigned a rh d positive as a test result by the instrument.Sample 2 was completed immediately afterward sample 1.The false blood group result was observed once for each sample, after qc run.Based on the data analyzed so far, we suspect that the instrument pc assigned both samples to rack 1, position 1 and 2.These racks were however occupied by qc samples.Due to this incorrect assignment of samples, wrong results were reported by the instrument.A warning message occurred just before the two samples were loaded: as to event log: "barcode scanner not functioning to reset the barcode scanner please close the drawer."; then "rack data on track 1 were discarded." the field service engineer was on site at the time of customer reporting and could confirm that the instrument is ok to run.The event has not been repeated.No other issues documented.Further root cause analysis is ongoing.Regarding the used reagent erytype s abd+rev.A1,b: the customer returned neither the patient samples that had caused the incorrect blood grouping test result nor the supposedly defective product.Therefore our quality control laboratory tested their retention sample of erytype s abd+rev.A1, b with different donor samples on tango optimo.All positive and negative reactions were correct.We did not observe any false positive reaction.Testing by our quality control laboratory confirmed that the allegedly defective lot of erytype s abd+rev.A1, b functions correctly.A review of the batch record documentation showed no irregularities which might have negatively affected the quality of the allegedly defective lot.An internal quality notification has been raised because of the delay in reporting this incident.
 
Event or Problem Description
The customer reported about false blood group result when testing with erytye s abd rev a1,b on tango optimo.One patient sample that was a true a rh d positive was assigned the test result o rh d negative.The customer received a discrepancy message from lis as historical data from the patient was known.Repeat testing and manual testing confirmed the true type of sample 1.The second sample (sample 2), a true type o rh d positive, was assigned a rh d positive as a test result by the instrument.Sample 2 was completed immediately afterward sample 1.The false blood group result was observed once for each sample, after qc run.The customer returned neither the patient samples that had caused the incorrect blood grouping test result nor the supposedly defective product.Therefore our quality control laboratory tested their retention sample of erytype s abd+rev.A1, b with different donor samples on tango optimo.All positive and negative reactions were correct.We did not observe any false positive reaction.Testing by our quality control laboratory confirmed that the allegedly defective lot of erytype s abd+rev.A1, b functions correctly.A review of the batch record documentation showed no irregularities which might have negatively affected the quality of the allegedly defective lot.The affected tango optimo and all data have been analyzed.The following root cause has been identified: while the sample rack was loaded on track 2, the rack present sensor of track 1 was flickering.This triggered a barcode scanner error and caused the scanned barcodes on track 2 to be mapped to track 1.This is a very unlikely event, since despite of several messages and warnings indicating an out of order or out of specification status of the instrument, the user decided to ignore the warnings and to continue processing the suspicious samples.There is no further reasonable mitigation conceivable preventing the user from that false reaction.We can confirm the instrument related complaint.However, there were also warning messages displayed, which the customer should have kept in mind in order to prevent such wrong results.An internal quality notification has been raised because of the delay in reporting this incident.
 
Additional Manufacturer Narrative
This is our final report on this incident.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TANGO OPTIMO
Common Device Name
AUTOMATED BLOOD BANK ANALYSER SYSTEM
Manufacturer (Section D)
BIO-RAD MEDICAL DIAGNOSTICS GMBH
industriestrasse 1
dreieich, hessen 63303
GM  63303
MDR Report Key7741735
Report Number9610824-2018-00048
Device Sequence Number1757093
Product Code KSZ
UDI-Device Identifier07611969961696
UDI-Public(01)07611969961696
Combination Product (Y/N)N
Initial Reporter StatePA
Initial Reporter CountryUS
PMA/510(K) Number
BK080013
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source health professional,user faci
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 09/14/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number848900010
Device Catalogue Number848 900 010
Was Device Available for Evaluation? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/31/2018
Supplement Date Received by Manufacturer05/31/2018
Initial Report FDA Received Date08/02/2018
Supplement Report FDA Received Date09/14/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
BROMELIN, LOT 880224000.; BROMELIN, LOT 880224000.; ERYTYPE S ABD+REV. A1,B, LOT 8737120.; ERYTYPE S ABD+REV. A1,B, LOT 8737120.; ERYTYPECELL A1, LOT 881501100.; ERYTYPECELL A1, LOT 881501100.; ERYTYPECELL B, LOT 881501100.; ERYTYPECELL B, LOT 881501100.
-
-