Model Number 86047
Medical Device Problem Code Contamination of Device Ingredient or Reagent (2901)
Health Effect - Clinical Code No Patient Involvement (2645)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
According to the reporter, the unit had residue in the cuff.There was no patient involvement.
 
Additional Manufacturer Narrative
Evaluation summary: five samples of device were received for evaluation.A visual inspection was performed and it was observed all the samples present an excess of mica (white powder) inside its cuff the failure mode excess of mica dust is confirmed.Information has been added to the database and trends will continue to be monitored if information is provided in the future, a supplemental report will be issued.
 
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SHILEY
Common Device Name
TUBE, TRACHEAL (W/WO CONNECTOR)
Manufacturer (Section D)
MMJ SA DE CV (USD)
ave henequen no 1181 desarroll
ciudad juarez,ci 32590
MX  32590
MDR Report Key7746965
Report Number2936999-2018-00484
Device Sequence Number1280334
Product Code BTR
UDI-Device Identifier50884522005645
UDI-Public50884522005645
Combination Product (Y/N)N
Initial Reporter StateWI
Initial Reporter CountryUS
PMA/510(K) Number
K871204
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source distributor,user facility
Initial Reporter Occupation Other
Type of Report Initial,Followup,Followup
Report Date (Section B) 10/29/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/22/2023
Device Model Number86047
Device Catalogue Number86047
Device Lot Number18A0492JZX
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer08/15/2018
Initial Date Received by Manufacturer 07/19/2018
Supplement Date Received by Manufacturer08/08/2018
10/02/2018
Initial Report FDA Received Date08/03/2018
Supplement Report FDA Received Date10/05/2018
10/29/2018
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-