WRIGHTS LANE SYNTHES USA PRODUCTS LLC 8MM TI CANNULATED TIBIAL NAIL-EX/315MM-STERILE; NAIL, FIXATION, BONE Back to Search Results
Model Number 04.004.243S
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Unspecified Infection (1930)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Patient id/initials, age/date of birth and weight are unknown.Unknown date in 2017.Complainant part is not expected to be returned for manufacturer review/investigation.Without a lot number the device history records review could not be completed.The investigation could not be completed; no conclusion could be drawn, as no product was received.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
It was reported that the patient is scheduled to undergo revision on (b)(6) 2018, to remove the following hardware: one (1) titanium cannulated tibial nail, one (1) locking compression plate (lcp) plate 6 holes, one (1) titanium locking screw 60mm, one (1) titanium locking screw 76mm, one (1) titanium locking screw 30mm, one (1) titanium locking screw 50mm and one (1) cortex screw self-tapping, due to osteomyelitis.The hardware was originally implanted for a fracture repair surgery to the right tibia on an unknown date in 2017.This is report 1 of 7 for (b)(4).
 
Event or Problem Description
The removal surgery scheduled for on (b)(6) 2018 has been canceled.Removal surgery will take place, but the rescheduled date is as yet unknown.
 
Additional Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Additional narrative: event: updated.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
8MM TI CANNULATED TIBIAL NAIL-EX/315MM-STERILE
Common Device Name
NAIL, FIXATION, BONE
Manufacturer (Section D)
WRIGHTS LANE SYNTHES USA PRODUCTS LLC
1302 wrights lane east
west chester PA 19380
MDR Report Key7758130
Report Number2939274-2018-53220
Device Sequence Number19258757
Product Code JDS
UDI-Device Identifier10886982083616
UDI-Public(01)10886982083616
Combination Product (Y/N)N
Initial Reporter StateHI
Initial Reporter CountryUS
PMA/510(K) Number
K040762
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Nurse
Type of Report Initial,Followup
Report Date (Section B) 07/19/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model Number04.004.243S
Device Catalogue Number04.004.243S
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 07/19/2018
Supplement Date Received by Manufacturer08/16/2018
Initial Report FDA Received Date08/07/2018
Supplement Report FDA Received Date09/13/2018
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
-
-