| Model Number |
10601 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Chest Pain (1776); Death (1802); Dyspnea (1816); Myocardial Infarction (1969); Cardiogenic Shock (2262)
|
| Date of Event |
04/02/2018
|
|
Type of Reportable Event
|
Death
|
|
Additional Manufacturer Narrative
|
|
Device is a combination product.Device evaluated by mfr: it is indicated that the device will not be returned for evaluation.If there is any further relevant information obtained, a supplemental medwatch will be filed.(b)(4).
|
| |
|
Event or Problem Description
|
|
(b)(6) clinical study.It was reported that the patient died.In (b)(6) 2017, the subject presented with stable angina (ccs classification: 3) and was referred for cardiac catheterization.Target lesion #1 was located in the proximal left circumflex artery (lcx) with 95% stenosis and was 6 mm long with a reference vessel diameter of 3.5 mm.Target lesion #1 was treated with pre-dilatation and placement of a 3.50 x 12 mm study stent.Following, post dilatation, the residual stenosis was 0%.The subject was discharged on dual antiplatelet therapy.In (b)(6) 2018, the subject was hospitalized due to acute non-st-segment elevation myocardial infarction with cardiogenic shock.The cardiac enzyme was found to be elevated (peak troponin i: 1.815 ng/ml; uln: 0.028 ng/ml).The patient was treated with medication and a 2.75 x 16 mm promus stent was implanted in the distal left anterior descending artery.Twenty-three days following the initial hospitalization, the patient died.Primary cause of death is acute non-st-segment elevation myocardial infarction with cardiogenic shock.
|
| |
|
Additional Manufacturer Narrative
|
|
Device is combination product updates were made to the following sections: describe event or problem relevant, tests/laboratory data, patient codes.This supplemental correction report is being filed to correct the report number in a previously submitted supplemental report (follow-up number 001) which was accepted by fda on 03:17 pm ct.The report number is being corrected from: 2134265-2018-64548 to: 2134265-2018-07188.
|
| |
|
Event or Problem Description
|
|
(b)(6) clinical study it was reported that the patient died.In (b)(6) 2017, the patient presented with stable angina (ccs classification: 3) and was referred for cardiac catheterization.Target lesion #1 was located in the proximal left circumflex artery (lcx) with 95% stenosis and was 6 mm long with a reference vessel diameter of 3.5 mm.Target lesion #1 was treated with pre-dilatation and placement of a 3.50 x12 mm study stent.Following, post dilatation, the residual stenosis was 0%.The patient was discharged on dual antiplatelet therapy the same day.In (b)(6) 2018, 348 days post index procedure, the patient presented to the hospital with progressive dyspnea and chest pain.Cardiac enzyme were found to be elevated consistent with myocardial infarction.The patient was also diagnosed with cardiogenic shock and was transferred to another hospital for further cardiology evaluation and intervention.The patient was referred for left heart catheterization and possible percutaneous coronary intervention (pci).The 95% stenosis of the distal lcx was treated with placement of 3.0 x 16mm promus premier drug eluting stent (des) with 0% residual stenosis.The patient condition improved; however, a recurrent episode of chest pain while being still on intravenous nitroglycerin occurred.Two days later, 350 days post index procedure, the 80% stenosis of the distal left anterior descending artery (lad) was treated with placement of a 2.75 x 16 mm promus premier des.On the same day, the 70-80% stenosis of the first diagonal was treated with balloon angioplasty.During hospitalization, the patient was diagnosed with acute systolic congestive heart failure which was medically managed.The patient's cardiogenic shock progressively worsened despite maximum inotrope support and given worsening respiratory distress, the patient was intubated fifteen days later.The patient remained on a ventilator with the maximum medical management including vasopressor pressure support as well as inotrope support.Given ongoing cardiogenic shock refractory to medical management, palliative medicine was consulted for goals of care discussion.The patients family elected to transition the patient to comfort care.Six days later, 371 days post index procedure, the patient was extubated and transitioned to comfort care and died the same day.The primary cause of death is cardiogenic shock.Per the death certificate the primary cause of death was cardiogenic shock and secondary cause for death was non-st-elevation myocardial infarction (nstemi).
|
| |
|